000884795 001__ 884795
000884795 005__ 20240711101425.0
000884795 0247_ $$2doi$$a10.3390/en13205490
000884795 0247_ $$2Handle$$a2128/26020
000884795 0247_ $$2altmetric$$aaltmetric:93527982
000884795 0247_ $$2WOS$$aWOS:000585273500001
000884795 037__ $$aFZJ-2020-03257
000884795 082__ $$a620
000884795 1001_ $$0P:(DE-Juel1)168194$$aSyranidou, Chloi$$b0$$eCorresponding author
000884795 245__ $$aIntegration of Large-Scale Variable Renewable Energy Sources into the Future European Power System: On the Curtailment Challenge
000884795 260__ $$aBasel$$bMDPI$$c2020
000884795 3367_ $$2DRIVER$$aarticle
000884795 3367_ $$2DataCite$$aOutput Types/Journal article
000884795 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1604322285_30098
000884795 3367_ $$2BibTeX$$aARTICLE
000884795 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000884795 3367_ $$00$$2EndNote$$aJournal Article
000884795 520__ $$aThe future European power system is projected to rely heavily on variable renewable energy sources (VRES), primarily wind and solar generation. However, the difficulties inherent to storing the primary energy of these sources is expected to pose significant challenges in terms of their integration into the system. To account for the high variability of renewable energy sources VRES, a novel pan-European dispatch model with high spatio-temporal resolution including load shifting is introduced here, providing highly detailed information regarding renewable energy curtailments for all Europe, typically underestimated in studies of future systems. which also includes modeling of load shifting. The model consists of four separate levels with different approaches for modeling thermal generation flexibility, storage units and demand as well as with spatial resolutions and generation dispatch formulations. Applying the developed model for the future European power system follows the results of corresponding transmission expansion planning studies, which are translated into the desired high spatial resolution. The analysis of the “large scale-RES” scenario for 2050 shows considerable congestion between northern and central Europe, which constitutes the primary cause of VRES curtailments of renewables. In addition, load shifting is shown to mostly improve the integration of solar energy into the system and not wind, which constitutes the dominant energy source for this scenario. Finally, the analysis of the curtailments time series using ideal converters shows that the best locations for their exploitation can be found in western Ireland and western Denmark.
000884795 536__ $$0G:(DE-HGF)POF3-134$$a134 - Electrolysis and Hydrogen (POF3-134)$$cPOF3-134$$fPOF III$$x0
000884795 588__ $$aDataset connected to CrossRef
000884795 7001_ $$0P:(DE-Juel1)130470$$aLinssen, Jochen$$b1$$ufzj
000884795 7001_ $$0P:(DE-Juel1)129928$$aStolten, Detlef$$b2$$ufzj
000884795 7001_ $$0P:(DE-Juel1)156460$$aRobinius, Martin$$b3
000884795 773__ $$0PERI:(DE-600)2437446-5$$a10.3390/en13205490$$gVol. 13, no. 20, p. 5490 -$$n20$$p5490 -$$tEnergies$$v13$$x1996-1073$$y2020
000884795 8564_ $$uhttps://juser.fz-juelich.de/record/884795/files/Invoice_MDPI_energies-946962_1417.58EUR.pdf
000884795 8564_ $$uhttps://juser.fz-juelich.de/record/884795/files/Invoice_MDPI_energies-946962_1417.58EUR.pdf?subformat=pdfa$$xpdfa
000884795 8564_ $$uhttps://juser.fz-juelich.de/record/884795/files/energies-13-05490-v2.pdf$$yOpenAccess
000884795 8564_ $$uhttps://juser.fz-juelich.de/record/884795/files/energies-13-05490-v2.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000884795 8767_ $$8946962$$92020-09-29$$d2020-09-29$$eAPC$$jZahlung erfolgt$$penergies-946962$$zIEK-3  Belegnr.: 1200157791
000884795 909CO $$ooai:juser.fz-juelich.de:884795$$pdnbdelivery$$popenCost$$pVDB$$pdriver$$pOpenAPC$$popen_access$$popenaire
000884795 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)168194$$aForschungszentrum Jülich$$b0$$kFZJ
000884795 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130470$$aForschungszentrum Jülich$$b1$$kFZJ
000884795 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129928$$aForschungszentrum Jülich$$b2$$kFZJ
000884795 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)156460$$aForschungszentrum Jülich$$b3$$kFZJ
000884795 9131_ $$0G:(DE-HGF)POF3-134$$1G:(DE-HGF)POF3-130$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lSpeicher und vernetzte Infrastrukturen$$vElectrolysis and Hydrogen$$x0
000884795 9141_ $$y2020
000884795 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2020-01-09
000884795 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000884795 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bENERGIES : 2018$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0501$$2StatID$$aDBCoverage$$bDOAJ Seal$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0500$$2StatID$$aDBCoverage$$bDOAJ$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0700$$2StatID$$aFees$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000884795 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0561$$2StatID$$aArticle Processing Charges$$f2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2020-01-09
000884795 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2020-01-09
000884795 920__ $$lyes
000884795 9201_ $$0I:(DE-Juel1)IEK-3-20101013$$kIEK-3$$lTechnoökonomische Systemanalyse$$x0
000884795 9801_ $$aAPC
000884795 9801_ $$aFullTexts
000884795 980__ $$ajournal
000884795 980__ $$aVDB
000884795 980__ $$aUNRESTRICTED
000884795 980__ $$aI:(DE-Juel1)IEK-3-20101013
000884795 980__ $$aAPC
000884795 981__ $$aI:(DE-Juel1)ICE-2-20101013