% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@ARTICLE{Uddin:886125,
      author       = {Uddin, Md. Shuza and Rafee, K. A. and Hossain, S. M. and
                      Khan, R. and Qaim, S. M.},
      title        = {{I}ntegral measurement of spectrum-averaged cross sections
                      of a few threshold reactions induced by fast neutrons of a
                      {TRIGA} reactor: comparison with integrated data from
                      excitation functions given in various data libraries},
      journal      = {Radiochimica acta},
      volume       = {108},
      number       = {7},
      issn         = {2193-3405},
      address      = {Berlin},
      publisher    = {De Gruyter},
      reportid     = {FZJ-2020-04288},
      pages        = {511 - 516},
      year         = {2020},
      abstract     = {Integral cross sections of the reactions 24Mg(n,p)24Na,
                      27Al(n,p)27Mg, 27Al(n,α)24Na, 58Ni(n,d + np)57Co and
                      60Ni(n,p)60Co were measured for the first time using the
                      fast neutron spectrum of a TRIGA reactor extending from 0.5
                      to 20 MeV. The values obtained in this work were comparable
                      with the recommended values for a pure 235U prompt fission
                      spectrum. The measured integral value was utilized for
                      integral test of excitation function of each reaction given
                      in some data libraries, namely ENDF/B-VIII.0, TENDL-2017,
                      IRDFF-1.05 and ROSFOND-2010. The integral measurements are
                      generally consistent with the integrated values within
                      $5 \%,$ except for a few cases, e. g. the reaction
                      60Ni(n,p)60Co, where the data libraries appear to need
                      improvement.},
      cin          = {INM-5},
      ddc          = {610},
      cid          = {I:(DE-Juel1)INM-5-20090406},
      pnm          = {573 - Neuroimaging (POF3-573)},
      pid          = {G:(DE-HGF)POF3-573},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:000551889200002},
      doi          = {10.1515/ract-2019-3212},
      url          = {https://juser.fz-juelich.de/record/886125},
}