000888505 001__ 888505
000888505 005__ 20210130010956.0
000888505 0247_ $$2doi$$a10.1002/pssa.201900925
000888505 0247_ $$2ISSN$$a0031-8965
000888505 0247_ $$2ISSN$$a1521-396X
000888505 0247_ $$2ISSN$$a1862-6300
000888505 0247_ $$2ISSN$$a1862-6319
000888505 0247_ $$2Handle$$a2128/26391
000888505 0247_ $$2WOS$$aWOS:000525922800001
000888505 037__ $$aFZJ-2020-04969
000888505 082__ $$a530
000888505 1001_ $$0P:(DE-Juel1)171355$$aWu, Changtong$$b0
000888505 245__ $$aA Highly Sensitive Amperometric Aptamer Biosensor for Adenosine Triphosphate Detection on a 64 Channel Gold Multielectrode Array
000888505 260__ $$aWeinheim$$bWiley-VCH$$c2020
000888505 3367_ $$2DRIVER$$aarticle
000888505 3367_ $$2DataCite$$aOutput Types/Journal article
000888505 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1607417808_11439
000888505 3367_ $$2BibTeX$$aARTICLE
000888505 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000888505 3367_ $$00$$2EndNote$$aJournal Article
000888505 520__ $$aHerein, an electrochemical aptamer biosensor based on a gold multielectrode array is reported for the detection of adenosine triphosphate (ATP), which is an important neurotransmitter in the central nervous system. The aptasensor possesses 64 individually addressable microelectrodes with a diameter of 24 μm, which is distributed over an area of 1 mm2. The electrodes are modified with an ATP‐specific aptamer, which is labeled with a ferrocene redox probe. It is demonstrated that the used chip fabrication and cleaning process generate microelectrode channels with similar electrochemical responses and electroactive surface areas. The immobilization of the aptamer on gold microelectrodes is optimized and the receptor density is determined to be (1.0 ± 0.44) × 1013 molecules cm−2. Concentration‐dependent alternating current voltammetry measurements exhibit a limit of detection of 0.30 × 10−9 m and a sensitivity of 2.4 nA logC. Furthermore, the sensor shows a high selectivity over analogous molecules and reproducible detection results in artificial cerebrospinal fluid. The sensor array is used to detect ATP via several channels of the same chip, showing high signal redundancy. A label‐free electrochemical, multichannel ATP aptasensor is demonstrated with high selectivity and subnanomolar sensitivity, which may be conducive to record this neurotransmitter in neuronal cell‐culture systems. 
000888505 536__ $$0G:(DE-HGF)POF3-523$$a523 - Controlling Configuration-Based Phenomena (POF3-523)$$cPOF3-523$$fPOF III$$x0
000888505 588__ $$aDataset connected to CrossRef
000888505 7001_ $$0P:(DE-Juel1)128713$$aOffenhäusser, Andreas$$b1
000888505 7001_ $$0P:(DE-Juel1)128707$$aMayer, Dirk$$b2$$eCorresponding author
000888505 773__ $$0PERI:(DE-600)1481091-8$$a10.1002/pssa.201900925$$gVol. 217, no. 13, p. 1900925 -$$n13$$p1900925 -$$tPhysica status solidi / A$$v217$$x1862-6319$$y2020
000888505 8564_ $$uhttps://juser.fz-juelich.de/record/888505/files/pssa.201900925.pdf$$yOpenAccess
000888505 909CO $$ooai:juser.fz-juelich.de:888505$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000888505 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)171355$$aForschungszentrum Jülich$$b0$$kFZJ
000888505 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)128713$$aForschungszentrum Jülich$$b1$$kFZJ
000888505 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)128707$$aForschungszentrum Jülich$$b2$$kFZJ
000888505 9131_ $$0G:(DE-HGF)POF3-523$$1G:(DE-HGF)POF3-520$$2G:(DE-HGF)POF3-500$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bKey Technologies$$lFuture Information Technology - Fundamentals, Novel Concepts and Energy Efficiency (FIT)$$vControlling Configuration-Based Phenomena$$x0
000888505 9141_ $$y2020
000888505 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2020-09-03
000888505 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2020-09-03
000888505 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000888505 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2020-09-03
000888505 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences$$d2020-09-03
000888505 915__ $$0StatID:(DE-HGF)3001$$2StatID$$aDEAL Wiley$$d2020-09-03$$wger
000888505 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2020-09-03
000888505 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2020-09-03
000888505 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2020-09-03
000888505 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000888505 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2020-09-03
000888505 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bPHYS STATUS SOLIDI A : 2018$$d2020-09-03
000888505 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2020-09-03
000888505 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2020-09-03$$wger
000888505 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2020-09-03
000888505 920__ $$lyes
000888505 9201_ $$0I:(DE-Juel1)IBI-3-20200312$$kIBI-3$$lBioelektronik$$x0
000888505 980__ $$ajournal
000888505 980__ $$aVDB
000888505 980__ $$aUNRESTRICTED
000888505 980__ $$aI:(DE-Juel1)IBI-3-20200312
000888505 9801_ $$aFullTexts