title = {{A}n {A}coustic {E}mission {A}nalysis of {G}lass-ceramic
{S}ealants for {S}olid {O}xide {F}uel and {E}lectrolysis
{C}ells {E}xposed to {T}orsional {T}est: {R}oom and
{H}igh-temperature {E}xperiments},
journal = {Journal of power sources},
volume = {46},
number = {27},
issn = {0378-7753},
address = {New York, NY [u.a.]},
publisher = {Elsevier},
reportid = {FZJ-2020-05360},
pages = {14724 - 14734},
year = {2021},
abstract = {The mechanical integrity of the sealant material is of key
importance for the long-term, reliable operation of solid
oxide fuel/electrolysis cell stacks. However, in-situ
monitoring and detection of potential failures in sealing
materials using classical electrochemical characterization
techniques are difficult tasks. Therefore, in this work, the
acoustic emission (AE) technique is applied to monitor and
characterize the failure process of a glass-ceramic sealant
exposed to torsional shear strength at both room and typical
stack operation temperature (750 °C). Hourglass-shaped
steel specimens are produced for the tests. A glass-ceramic
material with two different porosities is used to join the
specimens. The failure process is characterized in terms of
AE peak amplitude, AE cumulative hits and AE energy, as well
as the average frequency content of the signals. The results
indicate that the degree of microscopic damage can be
determined from the analysis of the AE energy and the
fracture mechanisms can be found by statistical analysis of
the average frequency of the signals. The fractured surfaces
are visualized by optical microscopy to unveil that
specimens with high porosity showed a fully cohesive
fracture pattern, while specimens with low porosity showed a
partially fracture pattern. As a result, AE method promises
to be a potential in-operando technique for monitoring
mechanical failure processes inside solid oxide cell
stacks.},
cin = {IEK-14 / IEK-2 / IAS-7 / ZEA-1},
ddc = {620},
cid = {I:(DE-Juel1)IEK-14-20191129 / I:(DE-Juel1)IEK-2-20101013 /
I:(DE-Juel1)IAS-7-20180321 / I:(DE-Juel1)ZEA-1-20090406},
pnm = {1231 - Electrochemistry for Hydrogen (POF4-123)},
pid = {G:(DE-HGF)POF4-1231},
typ = {PUB:(DE-HGF)16},
UT = {WOS:000639330400012},
doi = {10.1016/j.ijhydene.2021.01.232},
url = {https://juser.fz-juelich.de/record/888961},
}