001     888965
005     20240712113232.0
024 7 _ |a 10.1149/1945-7111/abdc79
|2 doi
024 7 _ |a 0013-4651
|2 ISSN
024 7 _ |a 0096-4743
|2 ISSN
024 7 _ |a 0096-4786
|2 ISSN
024 7 _ |a 1945-6859
|2 ISSN
024 7 _ |a 1945-7111
|2 ISSN
024 7 _ |a 2002-2015
|2 ISSN
024 7 _ |a 2156-7395
|2 ISSN
024 7 _ |a 2128/27087
|2 Handle
024 7 _ |a WOS:000613572100001
|2 WOS
024 7 _ |a altmetric:108088826
|2 altmetric
037 _ _ |a FZJ-2020-05364
082 _ _ |a 660
100 1 _ |a Peters, Roland
|0 P:(DE-Juel1)129901
|b 0
|e Corresponding author
|u fzj
245 _ _ |a Long-term Experience with a 5/15kW-class Reversible Solid Oxide Cell System
260 _ _ |a Bristol
|c 2021
|b IOP Publishing
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1611905609_31431
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a A 5/15 kW-class reversible Solid Oxide Cell (rSOC) system was developed and experimentally investigated at the Forschungszentrum Jülich GmbH. The main component of this system is the well-established Jülich Integrated Module, which consists of four 10-layer SOC sub-stacks with an active cell area per layer of 320 cm2. The other necessary system components, such as the evaporator, condenser and blowers are compactly arranged in the vicinity of the Integrated Module. The system's total operation time was more than 9000 h, in detail 2607 h in fuel cells, 6043 h in electrolysis and 448 h in hot standby mode. In fuel cell mode, a power of 5374 WDC at 0.5 A cm−2 at a fuel utilization of 97.3% was delivered, which resulted in a DC electrical system's efficiency of 62.7% (LHV). Furthermore, in electrolysis mode, a power of −14347 WDC was consumed at 0.89 A cm−2. At this operating point, the system's DC efficiency reached 70% at a steam utilization of 85%.
536 _ _ |a 123 - Chemische Energieträger (POF4-123)
|0 G:(DE-HGF)POF4-123
|c POF4-123
|x 0
|f POF IV
536 _ _ |a SOFC - Solid Oxide Fuel Cell (SOFC-20140602)
|0 G:(DE-Juel1)SOFC-20140602
|c SOFC-20140602
|x 1
|f SOFC
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a Frank, Matthias
|0 P:(DE-Juel1)166197
|b 1
700 1 _ |a Tiedemann, Wilfried
|0 P:(DE-Juel1)129932
|b 2
|u fzj
700 1 _ |a Hoven, Ingo
|0 P:(DE-Juel1)129859
|b 3
|u fzj
700 1 _ |a Deja, Robert
|0 P:(DE-Juel1)129838
|b 4
|u fzj
700 1 _ |a Kruse, Nicolas
|0 P:(DE-Juel1)180169
|b 5
|u fzj
700 1 _ |a Fang, Qingping
|0 P:(DE-Juel1)145945
|b 6
|u fzj
700 1 _ |a Blum, Ludger
|0 P:(DE-Juel1)129828
|b 7
|u fzj
700 1 _ |a Peters, Ralf
|0 P:(DE-Juel1)129902
|b 8
|u fzj
773 _ _ |a 10.1149/1945-7111/abdc79
|0 PERI:(DE-600)2002179-3
|p 014508
|t Journal of the Electrochemical Society
|v 168
|y 2021
|x 0013-4651
856 4 _ |u https://juser.fz-juelich.de/record/888965/files/Peters_2021_rSOC_JES_final.pdf
|y OpenAccess
909 C O |o oai:juser.fz-juelich.de:888965
|p openaire
|p open_access
|p driver
|p VDB
|p openCost
|p dnbdelivery
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)129901
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 1
|6 P:(DE-Juel1)166197
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)129932
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)129859
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)129838
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 5
|6 P:(DE-Juel1)180169
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 6
|6 P:(DE-Juel1)145945
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 7
|6 P:(DE-Juel1)129828
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 8
|6 P:(DE-Juel1)129902
913 0 _ |a DE-HGF
|b Energie
|l Speicher und vernetzte Infrastrukturen
|1 G:(DE-HGF)POF3-130
|0 G:(DE-HGF)POF3-135
|3 G:(DE-HGF)POF3
|2 G:(DE-HGF)POF3-100
|4 G:(DE-HGF)POF
|v Fuel Cells
|x 0
913 1 _ |a DE-HGF
|b Forschungsbereich Energie
|l Materialien und Technologien für die Energiewende (MTET)
|1 G:(DE-HGF)POF4-120
|0 G:(DE-HGF)POF4-123
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-100
|4 G:(DE-HGF)POF
|v Chemische Energieträger
|x 0
914 1 _ |y 2021
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1160
|2 StatID
|b Current Contents - Engineering, Computing and Technology
|d 2020-09-05
915 _ _ |a Creative Commons Attribution CC BY 4.0
|0 LIC:(DE-HGF)CCBY4
|2 HGFVOC
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1150
|2 StatID
|b Current Contents - Physical, Chemical and Earth Sciences
|d 2020-09-05
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2020-09-05
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
|d 2020-09-05
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b J ELECTROCHEM SOC : 2018
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2020-09-05
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2020-09-05
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)IEK-14-20191129
|k IEK-14
|l Elektrochemische Verfahrenstechnik
|x 0
980 1 _ |a FullTexts
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)IEK-14-20191129
980 _ _ |a APC
981 _ _ |a I:(DE-Juel1)IET-4-20191129


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21