000889897 001__ 889897
000889897 005__ 20240709082142.0
000889897 0247_ $$2doi$$a10.1016/j.applthermaleng.2019.114620
000889897 0247_ $$2ISSN$$a1359-4311
000889897 0247_ $$2ISSN$$a1873-5606
000889897 0247_ $$2Handle$$a2128/26848
000889897 0247_ $$2altmetric$$aaltmetric:71715832
000889897 0247_ $$2WOS$$aWOS:000503314300089
000889897 037__ $$aFZJ-2021-00505
000889897 082__ $$a690
000889897 1001_ $$0P:(DE-HGF)0$$aSeiler, Jan$$b0
000889897 245__ $$aCapillary-assisted evaporation of water from finned tubes – Impacts of experimental setups and dynamics
000889897 260__ $$aAmsterdam [u.a.]$$bElsevier Science$$c2020
000889897 3367_ $$2DRIVER$$aarticle
000889897 3367_ $$2DataCite$$aOutput Types/Journal article
000889897 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1611165894_7512
000889897 3367_ $$2BibTeX$$aARTICLE
000889897 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000889897 3367_ $$00$$2EndNote$$aJournal Article
000889897 520__ $$aCapillary-assisted thin-film evaporation is a promising approach to overcome the heat transfer challenges associated with sub-atmospheric evaporation of water in refrigeration applications. Consequently, thin-film evaporation is currently studied in several labs. However, so far it has been unclear whether results from different labs can be compared. In this work, we therefore investigate – for the first time – the impact of experimental setups and procedures on sub-atmospheric capillary-assisted thin-film evaporation of the refrigerant water and deduce methodological recommendations for improving reliability and comparability of measurement results. We present results of evaporation from finned copper tubes with decreasing filling levels from two different experimental setups:At higher driving force, the resulting dynamics of logarithmic mean temperature differences, heat flows and overall heat transfer coefficients determined in both setups are generally in good agreement but absolute values show deviations of up to 24%. For lower driving forces, the results are identical within uncertainty of measurement. We conclude that the impact of experimental setup is important when comparing absolute values from different setups, but obtaining comparable results is generally possible.
000889897 536__ $$0G:(DE-HGF)POF3-899$$a899 - ohne Topic (POF3-899)$$cPOF3-899$$fPOF III$$x0
000889897 588__ $$aDataset connected to CrossRef
000889897 7001_ $$0P:(DE-HGF)0$$aVolmer, Rahel$$b1
000889897 7001_ $$0P:(DE-HGF)0$$aKrakau, Dennis$$b2
000889897 7001_ $$0P:(DE-HGF)0$$aPöhls, Julien$$b3
000889897 7001_ $$0P:(DE-HGF)0$$aOssenkopp, Franziska$$b4
000889897 7001_ $$0P:(DE-HGF)0$$aSchnabel, Lena$$b5
000889897 7001_ $$0P:(DE-Juel1)172023$$aBardow, André$$b6$$eCorresponding author$$ufzj
000889897 773__ $$0PERI:(DE-600)2019322-1$$a10.1016/j.applthermaleng.2019.114620$$gVol. 165, p. 114620 -$$p114620 -$$tApplied thermal engineering$$v165$$x1359-4311$$y2020
000889897 8564_ $$uhttps://juser.fz-juelich.de/record/889897/files/2019_09_25_Manuscript_Experimental_analysis_revision.pdf$$yPublished on 2019-11-04. Available in OpenAccess from 2021-11-04.
000889897 909CO $$ooai:juser.fz-juelich.de:889897$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000889897 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b0$$kRWTH
000889897 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b2$$kRWTH
000889897 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)172023$$aForschungszentrum Jülich$$b6$$kFZJ
000889897 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-Juel1)172023$$aRWTH Aachen$$b6$$kRWTH
000889897 9131_ $$0G:(DE-HGF)POF3-899$$1G:(DE-HGF)POF3-890$$2G:(DE-HGF)POF3-800$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bProgrammungebundene Forschung$$lohne Programm$$vohne Topic$$x0
000889897 9141_ $$y2020
000889897 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2020-08-28
000889897 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2020-08-28
000889897 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2020-08-28
000889897 915__ $$0LIC:(DE-HGF)CCBYNCND4$$2HGFVOC$$aCreative Commons Attribution-NonCommercial-NoDerivs CC BY-NC-ND 4.0
000889897 915__ $$0StatID:(DE-HGF)0530$$2StatID$$aEmbargoed OpenAccess
000889897 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bAPPL THERM ENG : 2018$$d2020-08-28
000889897 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2020-08-28
000889897 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2020-08-28
000889897 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2020-08-28
000889897 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2020-08-28
000889897 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2020-08-28$$wger
000889897 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2020-08-28
000889897 920__ $$lyes
000889897 9201_ $$0I:(DE-Juel1)IEK-10-20170217$$kIEK-10$$lModellierung von Energiesystemen$$x0
000889897 9801_ $$aFullTexts
000889897 980__ $$ajournal
000889897 980__ $$aVDB
000889897 980__ $$aUNRESTRICTED
000889897 980__ $$aI:(DE-Juel1)IEK-10-20170217
000889897 981__ $$aI:(DE-Juel1)ICE-1-20170217