001     889897
005     20240709082142.0
024 7 _ |a 10.1016/j.applthermaleng.2019.114620
|2 doi
024 7 _ |a 1359-4311
|2 ISSN
024 7 _ |a 1873-5606
|2 ISSN
024 7 _ |a 2128/26848
|2 Handle
024 7 _ |a altmetric:71715832
|2 altmetric
024 7 _ |a WOS:000503314300089
|2 WOS
037 _ _ |a FZJ-2021-00505
082 _ _ |a 690
100 1 _ |a Seiler, Jan
|0 P:(DE-HGF)0
|b 0
245 _ _ |a Capillary-assisted evaporation of water from finned tubes – Impacts of experimental setups and dynamics
260 _ _ |a Amsterdam [u.a.]
|c 2020
|b Elsevier Science
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1611165894_7512
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Capillary-assisted thin-film evaporation is a promising approach to overcome the heat transfer challenges associated with sub-atmospheric evaporation of water in refrigeration applications. Consequently, thin-film evaporation is currently studied in several labs. However, so far it has been unclear whether results from different labs can be compared. In this work, we therefore investigate – for the first time – the impact of experimental setups and procedures on sub-atmospheric capillary-assisted thin-film evaporation of the refrigerant water and deduce methodological recommendations for improving reliability and comparability of measurement results. We present results of evaporation from finned copper tubes with decreasing filling levels from two different experimental setups:At higher driving force, the resulting dynamics of logarithmic mean temperature differences, heat flows and overall heat transfer coefficients determined in both setups are generally in good agreement but absolute values show deviations of up to 24%. For lower driving forces, the results are identical within uncertainty of measurement. We conclude that the impact of experimental setup is important when comparing absolute values from different setups, but obtaining comparable results is generally possible.
536 _ _ |a 899 - ohne Topic (POF3-899)
|0 G:(DE-HGF)POF3-899
|c POF3-899
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a Volmer, Rahel
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Krakau, Dennis
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Pöhls, Julien
|0 P:(DE-HGF)0
|b 3
700 1 _ |a Ossenkopp, Franziska
|0 P:(DE-HGF)0
|b 4
700 1 _ |a Schnabel, Lena
|0 P:(DE-HGF)0
|b 5
700 1 _ |a Bardow, André
|0 P:(DE-Juel1)172023
|b 6
|e Corresponding author
|u fzj
773 _ _ |a 10.1016/j.applthermaleng.2019.114620
|g Vol. 165, p. 114620 -
|0 PERI:(DE-600)2019322-1
|p 114620 -
|t Applied thermal engineering
|v 165
|y 2020
|x 1359-4311
856 4 _ |u https://juser.fz-juelich.de/record/889897/files/2019_09_25_Manuscript_Experimental_analysis_revision.pdf
|y Published on 2019-11-04. Available in OpenAccess from 2021-11-04.
909 C O |o oai:juser.fz-juelich.de:889897
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 0
|6 P:(DE-HGF)0
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 2
|6 P:(DE-HGF)0
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 6
|6 P:(DE-Juel1)172023
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 6
|6 P:(DE-Juel1)172023
913 1 _ |a DE-HGF
|b Programmungebundene Forschung
|l ohne Programm
|1 G:(DE-HGF)POF3-890
|0 G:(DE-HGF)POF3-899
|3 G:(DE-HGF)POF3
|2 G:(DE-HGF)POF3-800
|4 G:(DE-HGF)POF
|v ohne Topic
|x 0
914 1 _ |y 2020
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2020-08-28
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2020-08-28
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1160
|2 StatID
|b Current Contents - Engineering, Computing and Technology
|d 2020-08-28
915 _ _ |a Creative Commons Attribution-NonCommercial-NoDerivs CC BY-NC-ND 4.0
|0 LIC:(DE-HGF)CCBYNCND4
|2 HGFVOC
915 _ _ |a Embargoed OpenAccess
|0 StatID:(DE-HGF)0530
|2 StatID
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b APPL THERM ENG : 2018
|d 2020-08-28
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2020-08-28
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2020-08-28
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
|d 2020-08-28
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2020-08-28
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
|d 2020-08-28
|w ger
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2020-08-28
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)IEK-10-20170217
|k IEK-10
|l Modellierung von Energiesystemen
|x 0
980 1 _ |a FullTexts
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)IEK-10-20170217
981 _ _ |a I:(DE-Juel1)ICE-1-20170217


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21