520 _ _ |a

Nitrogen dioxide (NO2) and nitrogen monoxide (NO) govern the photochemical processes in the troposphere. Although nitrogen oxides have been measured for decades, their quantification remains challenging. The MetNO2 (Metrology for Nitrogen Dioxide) project of the European Metrology Programme for Innovation and Research (EMPIR) aims to improve the accuracy of NO2 measurements.

In total 15 instruments were intercompared at the World Calibration Centre for nitrogen oxides (WCC-NOx) in Jülich in autumn 2019 within the project. In addition to chemiluminescence detectors (CLD), the instruments encompassed Quantum Cascade Laser Absorption Spectrometers (QCLAS), Iterative CAvity-enhanced Differential optical absorption spectrometers (ICAD) and Cavity Attenuated Phase Shift (CAPS) spectrometers.

During the campaign, air from a gas phase titration unit, air from the environmental chamber SAPHIR or outside air was provided to the instruments via a common inlet line. The participants calibrated their instruments prior and after the campaign with their own calibration procedures. During the campaign, the common inlet line was used for daily calibration to compare standards, calibration techniques and sensitivity drifts of the instruments. NO2 for calibration was provided either by gas phase titration from NO, from permeation tubes or from gas mixtures produced within the MetNO2 project.

It was observed that measurements by chemiluminescence or CAPS instruments are prone to interferences from humidity and ozone. However, in most cases data can be corrected. Alkyl nitrates and reactive alkenes were also observed to cause interferences in some instruments, while isobutyl nitrite was found to be photolyzed by photolytic converters.

Finally, measurements in ambient air were compared. The nitrogen oxide observations were accompanied with measurements of hydroxyl radical (OH) reactivity and reactive nitrogen species as nitrous acid (HONO), dinitrogen pentoxide (N2O5), and chloryl nitrate (ClNO2). Detailed results of the intercomparison will be presented.


536 _ _ |0 G:(DE-HGF)POF3-243
|a 243 - Tropospheric trace substances and their transformation processes (POF3-243)
|c POF3-243
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
773 _ _ |a 10.5194/egusphere-egu2020-6069
909 C O |o oai:juser.fz-juelich.de:890283
|p VDB
910 1 _ |0 I:(DE-588b)5008462-8
|6 P:(DE-Juel1)2367
|a Forschungszentrum Jülich
|b 0
|k FZJ
913 1 _ |0 G:(DE-HGF)POF3-243
|1 G:(DE-HGF)POF3-240
|2 G:(DE-HGF)POF3-200
|3 G:(DE-HGF)POF3
|4 G:(DE-HGF)POF
|a DE-HGF
|b Erde und Umwelt
|l Atmosphäre und Klima
|v Tropospheric trace substances and their transformation processes
|x 0
914 1 _ |y 2020
920 1 _ |0 I:(DE-Juel1)IEK-8-20101013
|k IEK-8
|l Troposphäre
|x 0
980 _ _ |a conf
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)IEK-8-20101013
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)ICE-3-20101013


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21