TY - JOUR
AU - Knieps, A.
AU - Liang, Y.
AU - Drews, P.
AU - Endler, M.
AU - Grulke, O.
AU - Huang, Z.
AU - Killer, C.
AU - Liu, S.
AU - Nicolai, D.
AU - Rahbarnia, K.
AU - Sandri, N.
AU - Satheeswaran, G.
TI - Design and characteristics of a low-frequency magnetic probe for magnetic profile measurements at Wendelstein 7-X
JO - Review of scientific instruments
VL - 91
IS - 7
SN - 1089-7623
CY - [S.l.]
PB - American Institute of Physics
M1 - FZJ-2021-01478
SP - 073506 -
PY - 2020
AB - Equilibrium analysis in fusion devices usually relies on plasma pressure profiles and magnetic measurements outside the plasma. The kinetic profiles can give indirect information about the equilibrium magnetic field, while the stationary magnetic diagnostics cannot resolve current distributions on a smaller scale. This work presents a reciprocating magnetic probe, designed to provide direct plasma response measurements of the magnetic field in the scrape-off layer of Wendelstein 7-X. Hardware design and frequency characteristics are discussed, and a post-processing technique for extending the lower frequency cutoff of the integration scheme is presented
LB - PUB:(DE-HGF)16
C6 - 32752844
UR - <Go to ISI:>//WOS:000554065000002
DO - DOI:10.1063/5.0002193
UR - https://juser.fz-juelich.de/record/891389
ER -