000891906 001__ 891906
000891906 005__ 20250129092502.0
000891906 0247_ $$2doi$$a10.1093/gji/ggaa594
000891906 0247_ $$2WOS$$aWOS:000646864000014
000891906 037__ $$aFZJ-2021-01818
000891906 082__ $$a550
000891906 1001_ $$0P:(DE-Juel1)180342$$aWang, Haoran$$b0$$eCorresponding author
000891906 245__ $$aExperimental design to reduce inductive coupling in spectral electrical impedance tomography (sEIT) measurements
000891906 260__ $$aOxford$$bOxford Univ. Press$$c2021
000891906 3367_ $$2DRIVER$$aarticle
000891906 3367_ $$2DataCite$$aOutput Types/Journal article
000891906 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1618920047_19615
000891906 3367_ $$2BibTeX$$aARTICLE
000891906 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000891906 3367_ $$00$$2EndNote$$aJournal Article
000891906 520__ $$aSpectral electrical impedance tomography (sEIT) is a promising method to image the subsurface complex resistivity distribution in a broad frequency range (i.e. mHz to kHz). However, inductive coupling between cables is known to affect measurement accuracy for frequencies above 50 Hz. Previous studies have proposed correction methods, but these have not been widely adopted yet. In this study, we evaluated the influence of inductive coupling on the measured complex impedance for different electrode and cable configurations. We propose a novel index to evaluate the inductive coupling strength and use it to develop a filter that selects data with limited inductive coupling. In a first step, the inductive coupling strength of a fan-shaped and parallel cable layout were evaluated. It was found that the fan-shaped layout provided more measurements with low inductive coupling strength. Using a synthetic modelling study with a fan-shaped cable layout, we then showed that it is possible to achieve good inversion results without data correction if measurements with high inductive coupling strength are filtered out before inversion. In a final step, we use the novel filtering approach based on inductive coupling strength with actual surface sEIT measurements. The EIT inversion results based on the filtered data corresponded well with inversion results using data corrected for inductive coupling and also showed good spectral consistency. It was concluded that it is possible to achieve reliable inversion results without data correction for inductive coupling when a fan-shaped layout and configurations with sufficiently low inductive coupling strength are used.
000891906 536__ $$0G:(DE-HGF)POF4-217$$a217 - Für eine nachhaltige Bio-Ökonomie – von Ressourcen zu Produkten (POF4-217)$$cPOF4-217$$fPOF IV$$x0
000891906 7001_ $$0P:(DE-Juel1)129472$$aHuisman, Johan Alexander$$b1
000891906 7001_ $$0P:(DE-Juel1)133962$$aZimmermann, Egon$$b2
000891906 7001_ $$0P:(DE-Juel1)129549$$aVereecken, Harry$$b3
000891906 773__ $$0PERI:(DE-600)2006420-2$$a10.1093/gji/ggaa594$$n1$$p222-235$$tGeophysical journal international$$v225$$x0016-8009$$y2021
000891906 8564_ $$uhttps://juser.fz-juelich.de/record/891906/files/Manuscript_ICS_clean.pdf$$yRestricted
000891906 909CO $$ooai:juser.fz-juelich.de:891906$$pVDB:Earth_Environment$$pVDB
000891906 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)180342$$aForschungszentrum Jülich$$b0$$kFZJ
000891906 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129472$$aForschungszentrum Jülich$$b1$$kFZJ
000891906 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133962$$aForschungszentrum Jülich$$b2$$kFZJ
000891906 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129549$$aForschungszentrum Jülich$$b3$$kFZJ
000891906 9130_ $$0G:(DE-HGF)POF3-255$$1G:(DE-HGF)POF3-250$$2G:(DE-HGF)POF3-200$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bErde und Umwelt$$lTerrestrische Umwelt$$vTerrestrial Systems: From Observation to Prediction$$x0
000891906 9131_ $$0G:(DE-HGF)POF4-217$$1G:(DE-HGF)POF4-210$$2G:(DE-HGF)POF4-200$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Erde und Umwelt$$lErde im Wandel – Unsere Zukunft nachhaltig gestalten$$vFür eine nachhaltige Bio-Ökonomie – von Ressourcen zu Produkten$$x0
000891906 9141_ $$y2021
000891906 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2021-01-28$$wger
000891906 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2021-01-28
000891906 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2021-01-28
000891906 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2021-01-28
000891906 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences$$d2021-01-28
000891906 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2021-01-28
000891906 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2021-01-28
000891906 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bGEOPHYS J INT : 2019$$d2021-01-28
000891906 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2021-01-28
000891906 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2021-01-28
000891906 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2021-01-28
000891906 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2021-01-28
000891906 9201_ $$0I:(DE-Juel1)IBG-3-20101118$$kIBG-3$$lAgrosphäre$$x0
000891906 9201_ $$0I:(DE-Juel1)ZEA-2-20090406$$kZEA-2$$lZentralinstitut für Elektronik$$x1
000891906 980__ $$ajournal
000891906 980__ $$aVDB
000891906 980__ $$aI:(DE-Juel1)IBG-3-20101118
000891906 980__ $$aI:(DE-Juel1)ZEA-2-20090406
000891906 980__ $$aUNRESTRICTED
000891906 981__ $$aI:(DE-Juel1)PGI-4-20110106