000892834 001__ 892834
000892834 005__ 20240709082216.0
000892834 0247_ $$2doi$$a10.1016/j.electacta.2021.138526
000892834 0247_ $$2Handle$$a2128/29147
000892834 0247_ $$2altmetric$$aaltmetric:106494530
000892834 0247_ $$2WOS$$aWOS:000661937600003
000892834 037__ $$aFZJ-2021-02374
000892834 082__ $$a540
000892834 1001_ $$0P:(DE-Juel1)164855$$aLennartz, Peter$$b0$$ufzj
000892834 245__ $$aViscoelastic polyborosiloxanes as artificial solid electrolyte interphase on lithium metal anodes
000892834 260__ $$aNew York, NY [u.a.]$$bElsevier$$c2021
000892834 3367_ $$2DRIVER$$aarticle
000892834 3367_ $$2DataCite$$aOutput Types/Journal article
000892834 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1637846578_10843
000892834 3367_ $$2BibTeX$$aARTICLE
000892834 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000892834 3367_ $$00$$2EndNote$$aJournal Article
000892834 520__ $$aLithium metal is considered as outstanding anode material due to its superior specific capacity and high redox potential, despite that non-uniform lithium deposition and dissolution upon charging and discharging yields formation of reactive high surface area lithium (HSAL) and a brittle, inhomogeneous solid electrolyte interphase (SEI). As counterstrategy, artificial SEIs such as protective polymer layers can be designed to control lithium deposition. Herein, viscoelastic polyborosiloxanes (PBS) with varying degree of cross-linking (maximum storage modulus of 0.4 MPa) are synthesized and coated on lithium metal. Operando 7Li nuclear magnetic resonance spectroscopy illustrates that highly cross-linked PBS facilitates homogenous deposit morphologies, whereas merely cross-linked PBS does not show relevant effects compared to uncoated electrodes. Interphase analysis (impedance spectroscopy and distribution of relaxation times analysis) reveals increased interphase resistances for coated Li electrodes due to limited solvent uptake and provides a more detailed evaluation of resistive contributions from interphases compared to common equivalent circuit modeling. The beneficial effects of highly cross-linked PBS come at expense of higher resistance associated with a lower degree of swelling, hence emphasizing the complexity of Li deposition.
000892834 536__ $$0G:(DE-HGF)POF4-122$$a122 - Elektrochemische Energiespeicherung (POF4-122)$$cPOF4-122$$fPOF IV$$x0
000892834 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
000892834 7001_ $$0P:(DE-Juel1)171270$$aBorzutzki, Kristina Kerstin$$b1$$ufzj
000892834 7001_ $$0P:(DE-Juel1)166130$$aWinter, Martin$$b2$$ufzj
000892834 7001_ $$0P:(DE-Juel1)172047$$aBrunklaus, Gunther$$b3$$eCorresponding author$$ufzj
000892834 773__ $$0PERI:(DE-600)1483548-4$$a10.1016/j.electacta.2021.138526$$gVol. 388, p. 138526 -$$p138526$$tElectrochimica acta$$v388$$x0013-4686$$y2021
000892834 8564_ $$uhttps://juser.fz-juelich.de/record/892834/files/Viscoelastic.pdf$$yPublished on 2021-05-14. Available in OpenAccess from 2023-05-14.
000892834 909CO $$ooai:juser.fz-juelich.de:892834$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000892834 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)164855$$aForschungszentrum Jülich$$b0$$kFZJ
000892834 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)171270$$aForschungszentrum Jülich$$b1$$kFZJ
000892834 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)166130$$aForschungszentrum Jülich$$b2$$kFZJ
000892834 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)172047$$aForschungszentrum Jülich$$b3$$kFZJ
000892834 9131_ $$0G:(DE-HGF)POF4-122$$1G:(DE-HGF)POF4-120$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Energie$$lMaterialien und Technologien für die Energiewende (MTET)$$vElektrochemische Energiespeicherung$$x0
000892834 9130_ $$0G:(DE-HGF)POF3-131$$1G:(DE-HGF)POF3-130$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lSpeicher und vernetzte Infrastrukturen$$vElectrochemical Storage$$x0
000892834 9141_ $$y2021
000892834 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2021-01-30
000892834 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2021-01-30
000892834 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2021-01-30
000892834 915__ $$0LIC:(DE-HGF)CCBYNCND4$$2HGFVOC$$aCreative Commons Attribution-NonCommercial-NoDerivs CC BY-NC-ND 4.0
000892834 915__ $$0StatID:(DE-HGF)0530$$2StatID$$aEmbargoed OpenAccess
000892834 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bELECTROCHIM ACTA : 2019$$d2021-01-30
000892834 915__ $$0StatID:(DE-HGF)9905$$2StatID$$aIF >= 5$$bELECTROCHIM ACTA : 2019$$d2021-01-30
000892834 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2021-01-30
000892834 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2021-01-30
000892834 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2021-01-30
000892834 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences$$d2021-01-30
000892834 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2021-01-30
000892834 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2021-01-30$$wger
000892834 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2021-01-30
000892834 920__ $$lyes
000892834 9201_ $$0I:(DE-Juel1)IEK-12-20141217$$kIEK-12$$lHelmholtz-Institut Münster Ionenleiter für Energiespeicher$$x0
000892834 9801_ $$aFullTexts
000892834 980__ $$ajournal
000892834 980__ $$aVDB
000892834 980__ $$aUNRESTRICTED
000892834 980__ $$aI:(DE-Juel1)IEK-12-20141217
000892834 981__ $$aI:(DE-Juel1)IMD-4-20141217