TY - JOUR
AU - Neumaier, Bernd
AU - Spahn, Ingo
AU - Qaim, Syed M.
TI - Möglichkeiten und Grenzen der Nutzung kleiner Zyklotrone bei der Produktion medizinisch relevanter Radionuklide
JO - Der Nuklearmediziner
VL - 44
IS - 02
SN - 0723-7065
CY - Stuttgart
PB - Thieme
M1 - FZJ-2021-02617
SP - 120 - 126
PY - 2021
AB - Radionuclides for in vivo imaging studies as well as for internal radiotherapy are produced using both nuclear reactors and cyclotrons. In this contribution we discuss the possibilities of production of different types of radionuclides using a small medical cyclotron (Ep = 18 MeV; Ed = 9 MeV). Besides routine production of short-lived “standard” positron emitters 11C, 15O and 18F, several “non-standard” positron emitters like 64Cu, 86Y, 89Zr etc. could also be produced in quantities sufficient for extended positron emission tomography. It is, however, necessary to develop a suitable target system for irradiation of enriched material. In principle, it is then also possible to produce in small amounts a few SPECT radionuclides (67Ga, 111In, 123I) as well as therapy-related radionuclides (67Cu, 103Pd, 186Re)
LB - PUB:(DE-HGF)16
DO - DOI:10.1055/a-1380-7815
UR - https://juser.fz-juelich.de/record/893193
ER -