000893877 001__ 893877
000893877 005__ 20210810182035.0
000893877 0247_ $$2doi$$a10.1016/j.ultramic.2020.113196
000893877 0247_ $$2ISSN$$a0304-3991
000893877 0247_ $$2ISSN$$a1879-2723
000893877 0247_ $$2Handle$$a2128/28366
000893877 0247_ $$2pmid$$a33341079
000893877 0247_ $$2WOS$$aWOS:000612539600004
000893877 037__ $$aFZJ-2021-02889
000893877 041__ $$aEnglish
000893877 082__ $$a570
000893877 1001_ $$0P:(DE-HGF)0$$aMahr, Christoph$$b0$$eCorresponding author
000893877 245__ $$aAccurate measurement of strain at interfaces in 4D-STEM: A comparison of various methods
000893877 260__ $$aAmsterdam$$bElsevier Science$$c2021
000893877 3367_ $$2DRIVER$$aarticle
000893877 3367_ $$2DataCite$$aOutput Types/Journal article
000893877 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1627627453_16162
000893877 3367_ $$2BibTeX$$aARTICLE
000893877 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000893877 3367_ $$00$$2EndNote$$aJournal Article
000893877 520__ $$aStrain analysis by nano-beam electron diffraction allows for measurements of strain with nanometre resolution in a large field of view. This is done by evaluating distances between diffraction discs in diffraction patterns acquired while a focussed electron beam is scanned across the sample in a transmission electron microscope. The bottleneck of this method is a precise determination of diffraction disc positions, which suffers from the inner structure of the discs caused by dynamical diffraction. Electron beam precession is a tool that solves this problem but it is not commonly available in every microscope. Without precession significant progress has been reported recently by using patterned condenser apertures. The pattern of the aperture is reproduced in patterns of the diffraction discs allowing for a more precise position determination. In this report the accuracy of measured strain profiles using patterned apertures is investigated by evaluation of realistic simulations. This is done especially at interfaces between regions with different lattice plane spacing. It is found by evaluation of the simulations that measured strain profiles are more blurred and hence the accuracy at the interface is worse the more patterns are imprinted to the condenser aperture. An explanation of this effect is given and as a proof of principle a solution to this problem is provided applying geometric phase analysis ptychography
000893877 536__ $$0G:(DE-HGF)POF4-5351$$a5351 - Platform for Correlative, In Situ and Operando Characterization (POF4-535)$$cPOF4-535$$fPOF IV$$x0
000893877 536__ $$0G:(DE-HGF)VH-NG-1317$$amoreSTEM - Momentum-resolved Scanning Transmission Electron Microscopy (VH-NG-1317)$$cVH-NG-1317$$x1
000893877 536__ $$0G:(DE-HGF)ZT-I-0025$$aPtychography 4.0 - Proposal for a pilot project "Information & Data Science" (ZT-I-0025)$$cZT-I-0025$$x2
000893877 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
000893877 7001_ $$0P:(DE-Juel1)165314$$aMüller-Caspary, Knut$$b1$$ufzj
000893877 7001_ $$00000-0002-3054-6181$$aGrieb, Tim$$b2
000893877 7001_ $$0P:(DE-Juel1)178709$$aKrause, Florian$$b3
000893877 7001_ $$00000-0001-5391-6934$$aSchowalter, Marco$$b4
000893877 7001_ $$0P:(DE-HGF)0$$aRosenauer, Andreas$$b5
000893877 773__ $$0PERI:(DE-600)1479043-9$$a10.1016/j.ultramic.2020.113196$$gVol. 221, p. 113196 -$$p113196 -$$tUltramicroscopy$$v221$$x0304-3991$$y2021
000893877 8564_ $$uhttps://juser.fz-juelich.de/record/893877/files/Accurate%20measurement_MAHR_submitted.pdf$$yOpenAccess
000893877 909CO $$ooai:juser.fz-juelich.de:893877$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000893877 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)165314$$aForschungszentrum Jülich$$b1$$kFZJ
000893877 9101_ $$0I:(DE-HGF)0$$60000-0002-3054-6181$$aExternal Institute$$b2$$kExtern
000893877 9101_ $$0I:(DE-HGF)0$$60000-0001-5391-6934$$aExternal Institute$$b4$$kExtern
000893877 9131_ $$0G:(DE-HGF)POF4-535$$1G:(DE-HGF)POF4-530$$2G:(DE-HGF)POF4-500$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-5351$$aDE-HGF$$bKey Technologies$$lMaterials Systems Engineering$$vMaterials Information Discovery$$x0
000893877 9141_ $$y2021
000893877 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)1050$$2StatID$$aDBCoverage$$bBIOSIS Previews$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)1190$$2StatID$$aDBCoverage$$bBiological Abstracts$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bULTRAMICROSCOPY : 2019$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000893877 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2021-02-03
000893877 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2021-02-03$$wger
000893877 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2021-02-03
000893877 920__ $$lyes
000893877 9201_ $$0I:(DE-Juel1)ER-C-1-20170209$$kER-C-1$$lPhysik Nanoskaliger Systeme$$x0
000893877 980__ $$ajournal
000893877 980__ $$aVDB
000893877 980__ $$aUNRESTRICTED
000893877 980__ $$aI:(DE-Juel1)ER-C-1-20170209
000893877 9801_ $$aFullTexts