TY - JOUR
AU - Wallach, Daniel
AU - Palosuo, Taru
AU - Thorburn, Peter
AU - Hochman, Zvi
AU - Gourdain, Emmanuelle
AU - Andrianasolo, Fety
AU - Asseng, Senthold
AU - Basso, Bruno
AU - Buis, Samuel
AU - Crout, Neil
AU - Dibari, Camilla
AU - Dumont, Benjamin
AU - Ferrise, Roberto
AU - Gaiser, Thomas
AU - Garcia, Cecile
AU - Gayler, Sebastian
AU - Ghahramani, Afshin
AU - Hiremath, Santosh
AU - Hoek, Steven
AU - Horan, Heidi
AU - Hoogenboom, Gerrit
AU - Huang, Mingxia
AU - Jabloun, Mohamed
AU - Jansson, Per-Erik
AU - Jing, Qi
AU - Justes, Eric
AU - Kersebaum, Kurt Christian
AU - Klosterhalfen, Anne
AU - Launay, Marie
AU - Lewan, Elisabet
AU - Luo, Qunying
AU - Maestrini, Bernardo
AU - Mielenz, Henrike
AU - Moriondo, Marco
AU - Nariman Zadeh, Hasti
AU - Padovan, Gloria
AU - Olesen, Jørgen Eivind
AU - Poyda, Arne
AU - Priesack, Eckart
AU - Pullens, Johannes Wilhelmus Maria
AU - Qian, Budong
AU - Schütze, Niels
AU - Shelia, Vakhtang
AU - Souissi, Amir
AU - Specka, Xenia
AU - Srivastava, Amit Kumar
AU - Stella, Tommaso
AU - Streck, Thilo
AU - Trombi, Giacomo
AU - Wallor, Evelyn
AU - Wang, Jing
AU - Weber, Tobias K. D.
AU - Weihermüller, Lutz
AU - de Wit, Allard
AU - Wöhling, Thomas
AU - Xiao, Liujun
AU - Zhao, Chuang
AU - Zhu, Yan
AU - Seidel, Sabine J.
TI - The chaos in calibrating crop models: Lessons learned from a multi-model calibration exercise
JO - Environmental modelling & software
VL - 145
SN - 1364-8152
CY - Amsterdam [u.a.]
PB - Elsevier Science
M1 - FZJ-2021-03665
SP - 105206 -
PY - 2021
AB - Calibration, the estimation of model parameters based on fitting the model to experimental data, is among the first steps in many applications of process-based models and has an important impact on simulated values. We propose a novel method of developing guidelines for calibration of process-based models, based on development of recommendations for calibration of the phenology component of crop models. The approach was based on a multi-model study, where all teams were provided with the same data and asked to return simulations for the same conditions. All teams were asked to document in detail their calibration approach, including choices with respect to criteria for best parameters, choice of parameters to estimate and software. Based on an analysis of the advantages and disadvantages of the various choices, we propose calibration recommendations that cover a comprehensive list of decisions and that are based on actual practices.
LB - PUB:(DE-HGF)16
UR - <Go to ISI:>//WOS:000703667700002
DO - DOI:10.1016/j.envsoft.2021.105206
UR - https://juser.fz-juelich.de/record/897197
ER -