@INPROCEEDINGS{Steinbeck:903669,
author = {Steinbeck, Leon and Mester, Achim and Heinen, Stefan and
Zimmermann, Egon and Klotzsche, Anja and van Waasen, Stefan},
title = {{C}alibration concept for a {GPR} monitoring system and
methods for arrival time picking},
reportid = {FZJ-2021-05318},
year = {2021},
abstract = {Calibration of ground penetrating radar (GPR) measurement
systems isindispensable to enable quantitative and high
resolution data analysisespecially for high resolution soil
research as well as inversion approachesfor a wide range of
applications. This work presents a concept for an in
situcalibration of GPR monitoring systems which enables to
perform acalibration that is not solely based on signals
traveling in air. A classicalcalibration via signals
traveling in air is not feasible in our setup, since
thesystem is permanently positioned around a test specimen,
e.g. a soil column.The calibration concept is based on the
ability to use each antenna as bothtransmitter or receiver
and, thereby, perform reciprocal measurements.Initial test
measurements indicate the reliability of reciprocal
measurementsfor an in situ calibration of our monitoring
system with relative accuracies ofdown to 2 ps.},
month = {Dec},
date = {2021-12-01},
organization = {11th International Workshop on
Advanced Ground Penetrating Radar,
Valetta (Malta), 1 Dec 2021 - 4 Dec
2021},
subtyp = {After Call},
cin = {ZEA-2 / IBG-3},
cid = {I:(DE-Juel1)ZEA-2-20090406 / I:(DE-Juel1)IBG-3-20101118},
pnm = {2173 - Agro-biogeosystems: controls, feedbacks and impact
(POF4-217)},
pid = {G:(DE-HGF)POF4-2173},
typ = {PUB:(DE-HGF)6},
url = {https://juser.fz-juelich.de/record/903669},
}