000903804 245__ $$aA Compact, Self-Sustaining Fuel Cell Auxiliary Power Unit Operated on Diesel Fuel
000903804 260__ $$aBasel$$bMDPI$$c2021
000903804 3367_ $$2DRIVER$$aarticle
000903804 3367_ $$2DataCite$$aOutput Types/Journal article
000903804 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1640008142_26487
000903804 3367_ $$2BibTeX$$aARTICLE
000903804 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000903804 3367_ $$00$$2EndNote$$aJournal Article
000903804 520__ $$aA complete fuel cell-based auxiliary power unit in the 7.5 kWe power class utilizing diesel fuel was developed in accordance with the power density and start-up targets defined by the U.S. Department of Energy. The system includes a highly-integrated fuel processor with multifunctional reactors to facilitate autothermal reforming, the water-gas shift reaction, and catalytic combustion. It was designed with the help of process analyses, on the basis of which two commercial, high-temperature PEFC stacks and balance of plant components were selected. The complete system was packaged, which resulted in a volume of 187.5 l. After achieving a stable and reproducible stack performance based on a modified break-in procedure, a maximum power of 3.3 kWe was demonstrated in a single stack. Despite the strong deviation from design points resulting from a malfunctioning stack, all system functions could be validated. By scaling-up the performance of the functioning stack to the level of two stacks, a power density of 35 We l−1 could be estimated, which is close to the 40 We l−1 target. Furthermore, the start-up time could be reduced to less than 22 min, which exceeds the 30 min target. These results may bring diesel-based fuel cell auxiliary power units a step closer to use in real applications, which is supported by the demonstrated indicators
000903804 536__ $$0G:(DE-HGF)POF4-1231$$a1231 - Electrochemistry for Hydrogen (POF4-123)$$cPOF4-123$$fPOF IV$$x0
000903804 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
000903804 7001_ $$0P:(DE-Juel1)129906$$aPrawitz, Matthias$$b1
000903804 7001_ $$0P:(DE-Juel1)129935$$aTschauder, Andreas$$b2$$ufzj
000903804 7001_ $$0P:(DE-Juel1)171839$$aWeiske, Stefan$$b3$$ufzj
000903804 7001_ $$0P:(DE-Juel1)129898$$aPasel, Joachim$$b4$$ufzj
000903804 7001_ $$0P:(DE-Juel1)129902$$aPeters, Ralf$$b5
000903804 773__ $$0PERI:(DE-600)2437446-5$$a10.3390/en14185909$$gVol. 14, no. 18, p. 5909 -$$n18$$p5909 -$$tEnergies$$v14$$x1996-1073$$y2021
000903804 8564_ $$uhttps://juser.fz-juelich.de/record/903804/files/energies-14-05909-v2.pdf$$yOpenAccess
000903804 909CO $$ooai:juser.fz-juelich.de:903804$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000903804 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)207065$$aForschungszentrum Jülich$$b0$$kFZJ
000903804 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129906$$aForschungszentrum Jülich$$b1$$kFZJ
000903804 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129935$$aForschungszentrum Jülich$$b2$$kFZJ
000903804 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)171839$$aForschungszentrum Jülich$$b3$$kFZJ
000903804 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-Juel1)171839$$aRWTH Aachen$$b3$$kRWTH
000903804 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129898$$aForschungszentrum Jülich$$b4$$kFZJ
000903804 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129902$$aForschungszentrum Jülich$$b5$$kFZJ
000903804 9131_ $$0G:(DE-HGF)POF4-123$$1G:(DE-HGF)POF4-120$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1231$$aDE-HGF$$bForschungsbereich Energie$$lMaterialien und Technologien für die Energiewende (MTET)$$vChemische Energieträger$$x0
000903804 9141_ $$y2021
000903804 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2021-05-04
000903804 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000903804 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bENERGIES : 2019$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0501$$2StatID$$aDBCoverage$$bDOAJ Seal$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0500$$2StatID$$aDBCoverage$$bDOAJ$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0700$$2StatID$$aFees$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000903804 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0561$$2StatID$$aArticle Processing Charges$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2021-05-04
000903804 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2021-05-04
000903804 920__ $$lyes
000903804 9201_ $$0I:(DE-Juel1)IEK-14-20191129$$kIEK-14$$lElektrochemische Verfahrenstechnik$$x0
000903804 9801_ $$aFullTexts
000903804 980__ $$ajournal
000903804 980__ $$aVDB
000903804 980__ $$aUNRESTRICTED
000903804 980__ $$aI:(DE-Juel1)IEK-14-20191129
000903804 981__ $$aI:(DE-Juel1)IET-4-20191129