000904074 001__ 904074
000904074 005__ 20240708133437.0
000904074 0247_ $$2doi$$a10.1063/5.0042029
000904074 0247_ $$2ISSN$$a0034-6748
000904074 0247_ $$2ISSN$$a1089-7623
000904074 0247_ $$2ISSN$$a1527-2400
000904074 0247_ $$2Handle$$a2128/30447
000904074 0247_ $$2pmid$$a34243273
000904074 0247_ $$2WOS$$aWOS:000691996800003
000904074 037__ $$aFZJ-2021-05644
000904074 082__ $$a620
000904074 1001_ $$00000-0001-8997-743X$$aSerov, S. V.$$b0
000904074 245__ $$aMeasurement performance assessment for the ITER CXRS Edge diagnostic system
000904074 260__ $$a[S.l.]$$bAmerican Institute of Physics$$c2021
000904074 3367_ $$2DRIVER$$aarticle
000904074 3367_ $$2DataCite$$aOutput Types/Journal article
000904074 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1642780067_3620
000904074 3367_ $$2BibTeX$$aARTICLE
000904074 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000904074 3367_ $$00$$2EndNote$$aJournal Article
000904074 520__ $$aMeasurement performance assessment has been carried out for the latest design of the ITER Charge Exchange Recombination Spectroscopy (CXRS) Edge diagnostic system. Several plasma scenarios, covering all expected baseline operation regimes for ITER, were used. Various impurity (He, Be, C, and Ne) concentrations for the system whole spatial range (0.5 < r/a < 1.0) were considered. Statistical errors for the measurements of low-Z impurity temperature, density, and rotation velocity were calculated. Other non-statistical error sources were reviewed, including the presence of wall reflections, effects on the active charge-exchange line shape, calibration, and positioning uncertainties. Minimal impurity concentrations, allowing measurements with required accuracy, were obtained. It was shown that the CXRS Edge system will be able to measure primary plasma parameters with required accuracy, space, and time resolution
000904074 536__ $$0G:(DE-HGF)POF4-134$$a134 - Plasma-Wand-Wechselwirkung (POF4-134)$$cPOF4-134$$fPOF IV$$x0
000904074 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
000904074 7001_ $$0P:(DE-HGF)0$$aDe Bock, M.$$b1
000904074 7001_ $$0P:(DE-Juel1)167437$$avon Hellermann, M. G.$$b2
000904074 7001_ $$00000-0003-4937-8437$$aTugarinov, S. N.$$b3$$eCorresponding author
000904074 773__ $$0PERI:(DE-600)1472905-2$$a10.1063/5.0042029$$gVol. 92, no. 5, p. 053517 -$$n5$$p053517 -$$tReview of scientific instruments$$v92$$x0034-6748$$y2021
000904074 8564_ $$uhttps://juser.fz-juelich.de/record/904074/files/5.0042029.pdf$$yPublished on 2021-05-07. Available in OpenAccess from 2022-05-07.
000904074 909CO $$ooai:juser.fz-juelich.de:904074$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000904074 9131_ $$0G:(DE-HGF)POF4-134$$1G:(DE-HGF)POF4-130$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Energie$$lFusion$$vPlasma-Wand-Wechselwirkung$$x0
000904074 9141_ $$y2021
000904074 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)0530$$2StatID$$aEmbargoed OpenAccess
000904074 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bREV SCI INSTRUM : 2019$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)0430$$2StatID$$aNational-Konsortium$$d2021-02-02$$wger
000904074 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)0320$$2StatID$$aDBCoverage$$bPubMed Central$$d2021-02-02
000904074 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2021-02-02$$wger
000904074 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2021-02-02
000904074 9201_ $$0I:(DE-Juel1)IEK-4-20101013$$kIEK-4$$lPlasmaphysik$$x0
000904074 9801_ $$aFullTexts
000904074 980__ $$ajournal
000904074 980__ $$aVDB
000904074 980__ $$aUNRESTRICTED
000904074 980__ $$aI:(DE-Juel1)IEK-4-20101013
000904074 981__ $$aI:(DE-Juel1)IFN-1-20101013