001     904196
005     20240712112851.0
024 7 _ |a 10.1109/JESTPE.2020.2998056
|2 doi
024 7 _ |a 2168-6777
|2 ISSN
024 7 _ |a 2168-6785
|2 ISSN
024 7 _ |a WOS:000669369600009
|2 WOS
037 _ _ |a FZJ-2021-05766
082 _ _ |a 621.3
100 1 _ |a Wunderlich, Andrew S.
|0 P:(DE-HGF)0
|b 0
245 _ _ |a Protection Scheme for Fast Detection and Interruption of High-Impedance Faults on Rate-Limited DC Distribution Networks
260 _ _ |a [New York, NY]
|c 2021
|b IEEE
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1643102725_9617
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
500 _ _ |a Kein Zugriff auf Post-print
520 _ _ |a This article presents a protection scheme for dc power distribution systems based on a unique rate-limited operating mode. The concept of this protection scheme is that extremely slow ramp-rate limits can be imposed on the dc network voltage and all currents drawn from the network through control of the power electronic interfaces. Meanwhile, all fast transients produced by loads and DGs can be absorbed by local energy storage-typically a battery-behind the interface converter. The removal of all transients from the distribution network enables a very effective method to differentiate the normal operation from fault conditions, including high-impedance faults, such as vegetation faults and human-body faults. In the proposed scheme, the ramp rates of the current and voltage on the network are sensed by each interfaced converter to check for compliance with the defined rate limits. It is unlikely that a given fault on the network will comply with the stringently slow rate limits, so this scheme allows the system to quickly detect the fault and deploy suitable protections. Experimental results show that the presented protection scheme is capable of detecting and interrupting a human-body-impedance fault quickly enough to prevent electrocution on a dc distribution cable operating at voltages of 1000 V and above, leading to unprecedented safety on a power distribution network of this voltage level.
536 _ _ |a 1121 - Digitalization and Systems Technology for Flexibility Solutions (POF4-112)
|0 G:(DE-HGF)POF4-1121
|c POF4-112
|f POF IV
|x 0
588 _ _ |a Dataset connected to CrossRef, Journals: juser.fz-juelich.de
700 1 _ |a Bauer, Daniel
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Santi, Enrico
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Dougal, Roger A.
|0 P:(DE-HGF)0
|b 3
700 1 _ |a Benigni, Andrea
|0 P:(DE-Juel1)179029
|b 4
|u fzj
700 1 _ |a Bennett, Rob
|0 P:(DE-HGF)0
|b 5
700 1 _ |a Zubieta, Luis E.
|0 P:(DE-HGF)0
|b 6
773 _ _ |a 10.1109/JESTPE.2020.2998056
|g Vol. 9, no. 3, p. 2540 - 2549
|0 PERI:(DE-600)2686523-3
|n 3
|p 2540 - 2549
|t IEEE journal of emerging and selected topics in power electronics
|v 9
|y 2021
|x 2168-6777
856 4 _ |u https://juser.fz-juelich.de/record/904196/files/Protection_Scheme_for_Fast_Detection_and_Interruption_of_High-Impedance_Faults_on_Rate-Limited_DC_Distribution_Networks.pdf
|y Restricted
909 C O |o oai:juser.fz-juelich.de:904196
|p VDB
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)179029
913 1 _ |a DE-HGF
|b Forschungsbereich Energie
|l Energiesystemdesign (ESD)
|1 G:(DE-HGF)POF4-110
|0 G:(DE-HGF)POF4-112
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-100
|4 G:(DE-HGF)POF
|v Digitalisierung und Systemtechnik
|9 G:(DE-HGF)POF4-1121
|x 0
914 1 _ |y 2021
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2021-01-28
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2021-01-28
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2021-01-28
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1230
|2 StatID
|b Current Contents - Electronics and Telecommunications Collection
|d 2021-01-28
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2021-01-28
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1160
|2 StatID
|b Current Contents - Engineering, Computing and Technology
|d 2021-01-28
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2021-01-28
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2021-01-28
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b IEEE J EM SEL TOP P : 2019
|d 2021-01-28
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
|d 2021-01-28
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)IEK-10-20170217
|k IEK-10
|l Modellierung von Energiesystemen
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)IEK-10-20170217
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)ICE-1-20170217


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21