000904344 001__ 904344
000904344 005__ 20230123101834.0
000904344 0247_ $$2doi$$a10.3390/s21186161
000904344 0247_ $$2Handle$$a2128/33096
000904344 0247_ $$2pmid$$a34577368
000904344 0247_ $$2WOS$$aWOS:000701527700001
000904344 037__ $$aFZJ-2021-05914
000904344 082__ $$a620
000904344 1001_ $$0P:(DE-Juel1)128717$$aPoghossian, Arshak$$b0
000904344 245__ $$aAn Array of On-Chip Integrated, Individually Addressable Capacitive Field-Effect Sensors with Control Gate: Design and Modelling
000904344 260__ $$aBasel$$bMDPI$$c2021
000904344 3367_ $$2DRIVER$$aarticle
000904344 3367_ $$2DataCite$$aOutput Types/Journal article
000904344 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1671012366_29274
000904344 3367_ $$2BibTeX$$aARTICLE
000904344 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000904344 3367_ $$00$$2EndNote$$aJournal Article
000904344 520__ $$aThe on-chip integration of multiple biochemical sensors based on field-effect electrolyte-insulator-semiconductor capacitors (EISCAP) is challenging due to technological difficulties in realization of electrically isolated EISCAPs on the same Si chip. In this work, we present a new simple design for an array of on-chip integrated, individually electrically addressable EISCAPs with an additional control gate (CG-EISCAP). The existence of the CG enables an addressable activation or deactivation of on-chip integrated individual CG-EISCAPs by simple electrical switching the CG of each sensor in various setups, and makes the new design capable for multianalyte detection without cross-talk effects between the sensors in the array. The new designed CG-EISCAP chip was modelled in so-called floating/short-circuited and floating/capacitively-coupled setups, and the corresponding electrical equivalent circuits were developed. In addition, the capacitance-voltage curves of the CG-EISCAP chip in different setups were simulated and compared with that of a single EISCAP sensor. Moreover, the sensitivity of the CG-EISCAP chip to surface potential changes induced by biochemical reactions was simulated and an impact of different parameters, such as gate voltage, insulator thickness and doping concentration in Si, on the sensitivity has been discussed
000904344 536__ $$0G:(DE-HGF)POF4-5241$$a5241 - Molecular Information Processing in Cellular Systems (POF4-524)$$cPOF4-524$$fPOF IV$$x0
000904344 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
000904344 7001_ $$0P:(DE-HGF)0$$aWelden, Rene$$b1
000904344 7001_ $$00000-0003-0662-7296$$aBuniatyan, Vahe V.$$b2
000904344 7001_ $$0P:(DE-Juel1)128727$$aSchöning, Michael J.$$b3$$eCorresponding author
000904344 773__ $$0PERI:(DE-600)2052857-7$$a10.3390/s21186161$$gVol. 21, no. 18, p. 6161 -$$n18$$p6161 -$$tSensors$$v21$$x1424-8220$$y2021
000904344 8564_ $$uhttps://juser.fz-juelich.de/record/904344/files/sensors-21-06161-v2.pdf$$yOpenAccess
000904344 909CO $$ooai:juser.fz-juelich.de:904344$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000904344 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)128717$$aForschungszentrum Jülich$$b0$$kFZJ
000904344 9101_ $$0I:(DE-HGF)0$$6P:(DE-Juel1)128717$$a IBI-3$$b0
000904344 9101_ $$0I:(DE-HGF)0$$60000-0003-0662-7296$$aExternal Institute$$b2$$kExtern
000904344 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)128727$$aForschungszentrum Jülich$$b3$$kFZJ
000904344 9131_ $$0G:(DE-HGF)POF4-524$$1G:(DE-HGF)POF4-520$$2G:(DE-HGF)POF4-500$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-5241$$aDE-HGF$$bKey Technologies$$lNatural, Artificial and Cognitive Information Processing$$vMolecular and Cellular Information Processing$$x0
000904344 9141_ $$y2022
000904344 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2021-05-04
000904344 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000904344 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bSENSORS-BASEL : 2019$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0501$$2StatID$$aDBCoverage$$bDOAJ Seal$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0500$$2StatID$$aDBCoverage$$bDOAJ$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0700$$2StatID$$aFees$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000904344 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0561$$2StatID$$aArticle Processing Charges$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0320$$2StatID$$aDBCoverage$$bPubMed Central$$d2021-05-04
000904344 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2021-05-04
000904344 9201_ $$0I:(DE-Juel1)IBI-3-20200312$$kIBI-3$$lBioelektronik$$x0
000904344 9801_ $$aFullTexts
000904344 980__ $$ajournal
000904344 980__ $$aVDB
000904344 980__ $$aUNRESTRICTED
000904344 980__ $$aI:(DE-Juel1)IBI-3-20200312