| Home > Publications database > Magnesium Substitution in Ni‐Rich NMC Layered Cathodes for High‐Energy Lithium Ion Batteries > print |
| 001 | 905130 | ||
| 005 | 20240712113130.0 | ||
| 024 | 7 | _ | |a 10.1002/aenm.202103045 |2 doi |
| 024 | 7 | _ | |a 1614-6832 |2 ISSN |
| 024 | 7 | _ | |a 1614-6840 |2 ISSN |
| 024 | 7 | _ | |a 2128/30814 |2 Handle |
| 024 | 7 | _ | |a altmetric:120293199 |2 altmetric |
| 024 | 7 | _ | |a WOS:000738814800001 |2 WOS |
| 037 | _ | _ | |a FZJ-2022-00422 |
| 082 | _ | _ | |a 050 |
| 100 | 1 | _ | |a Gomez-Martin, Aurora |0 0000-0001-7053-3986 |b 0 |e Corresponding author |
| 245 | _ | _ | |a Magnesium Substitution in Ni‐Rich NMC Layered Cathodes for High‐Energy Lithium Ion Batteries |
| 260 | _ | _ | |a Weinheim |c 2022 |b Wiley-VCH |
| 336 | 7 | _ | |a article |2 DRIVER |
| 336 | 7 | _ | |a Output Types/Journal article |2 DataCite |
| 336 | 7 | _ | |a Journal Article |b journal |m journal |0 PUB:(DE-HGF)16 |s 1646143393_3719 |2 PUB:(DE-HGF) |
| 336 | 7 | _ | |a ARTICLE |2 BibTeX |
| 336 | 7 | _ | |a JOURNAL_ARTICLE |2 ORCID |
| 336 | 7 | _ | |a Journal Article |0 0 |2 EndNote |
| 520 | _ | _ | |a Ni-rich LiNi1−x−yMnxCoyO2 (NMC) layered oxides are promising cathode materials for high-energy density lithium ion batteries but suffer from severe capacity fading upon cycling. Elemental substitution (= doping) with Mg has repeatedly attracted attention in NMC materials to overcome instability problems at reasonable cost, yet rational compositional tuning is needed to guarantee sufficient cycle life without compromising energy density on the material level. Herein, a series of Mg-substituted NMC materials with 90 mol% Ni are investigated regarding key performance metrics in NMC || graphite full-cells benchmarked against LiNi0.80Mn0.10Co0.10O2 and LiNi0.90Mn0.05Co0.05O2 synthetized using the same co-precipitation route. A linear correlation between cycle life and attainable gravimetric capacities is demonstrated, which are directly influenced by the degree of Mg substitution and the amount of Li+ cycled upon (de-)lithiation processes. A Mg content <2 mol% should be considered to take notable benefit from the increase in Ni content from 80 to 90 mol% to achieve a higher energy density. The present study highlights the importance of evaluating the true implications of elemental substitution on cell performance and is expected to be an insightful guideline for the future development of NMC-type cathode materials in particular with high Ni and low Co content. |
| 536 | _ | _ | |a 1221 - Fundamentals and Materials (POF4-122) |0 G:(DE-HGF)POF4-1221 |c POF4-122 |f POF IV |x 0 |
| 588 | _ | _ | |a Dataset connected to CrossRef, Journals: juser.fz-juelich.de |
| 700 | 1 | _ | |a Reissig, Friederike |0 P:(DE-HGF)0 |b 1 |
| 700 | 1 | _ | |a Frankenstein, Lars |0 P:(DE-HGF)0 |b 2 |
| 700 | 1 | _ | |a Heidbüchel, Marcel |0 P:(DE-HGF)0 |b 3 |
| 700 | 1 | _ | |a Winter, Martin |0 P:(DE-Juel1)166130 |b 4 |
| 700 | 1 | _ | |a Placke, Tobias |0 0000-0002-2097-5193 |b 5 |
| 700 | 1 | _ | |a Schmuch, Richard |0 0000-0002-5670-0327 |b 6 |e Corresponding author |
| 773 | _ | _ | |a 10.1002/aenm.202103045 |g p. 2103045 - |0 PERI:(DE-600)2594556-7 |n 8 |p 2103045 |t Advanced energy materials |v 12 |y 2022 |x 1614-6832 |
| 856 | 4 | _ | |u https://juser.fz-juelich.de/record/905130/files/Advanced%20Energy%20Materials%20-%202022%20-%20Gomez%E2%80%90Martin%20-%20Magnesium%20Substitution%20in%20Ni%E2%80%90Rich%20NMC%20Layered%20Cathodes%20for%20High%E2%80%90Energy.pdf |y OpenAccess |
| 909 | C | O | |o oai:juser.fz-juelich.de:905130 |p openaire |p open_access |p VDB |p driver |p dnbdelivery |
| 910 | 1 | _ | |a Forschungszentrum Jülich |0 I:(DE-588b)5008462-8 |k FZJ |b 4 |6 P:(DE-Juel1)166130 |
| 913 | 1 | _ | |a DE-HGF |b Forschungsbereich Energie |l Materialien und Technologien für die Energiewende (MTET) |1 G:(DE-HGF)POF4-120 |0 G:(DE-HGF)POF4-122 |3 G:(DE-HGF)POF4 |2 G:(DE-HGF)POF4-100 |4 G:(DE-HGF)POF |v Elektrochemische Energiespeicherung |9 G:(DE-HGF)POF4-1221 |x 0 |
| 914 | 1 | _ | |y 2022 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0160 |2 StatID |b Essential Science Indicators |d 2021-01-30 |
| 915 | _ | _ | |a Creative Commons Attribution CC BY 4.0 |0 LIC:(DE-HGF)CCBY4 |2 HGFVOC |
| 915 | _ | _ | |a DEAL Wiley |0 StatID:(DE-HGF)3001 |2 StatID |d 2021-01-30 |w ger |
| 915 | _ | _ | |a WoS |0 StatID:(DE-HGF)0113 |2 StatID |b Science Citation Index Expanded |d 2021-01-30 |
| 915 | _ | _ | |a OpenAccess |0 StatID:(DE-HGF)0510 |2 StatID |
| 915 | _ | _ | |a JCR |0 StatID:(DE-HGF)0100 |2 StatID |b ADV ENERGY MATER : 2021 |d 2022-11-12 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0200 |2 StatID |b SCOPUS |d 2022-11-12 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0300 |2 StatID |b Medline |d 2022-11-12 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0600 |2 StatID |b Ebsco Academic Search |d 2022-11-12 |
| 915 | _ | _ | |a Peer Review |0 StatID:(DE-HGF)0030 |2 StatID |b ASC |d 2022-11-12 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0199 |2 StatID |b Clarivate Analytics Master Journal List |d 2022-11-12 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1160 |2 StatID |b Current Contents - Engineering, Computing and Technology |d 2022-11-12 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0150 |2 StatID |b Web of Science Core Collection |d 2022-11-12 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1150 |2 StatID |b Current Contents - Physical, Chemical and Earth Sciences |d 2022-11-12 |
| 915 | _ | _ | |a IF >= 25 |0 StatID:(DE-HGF)9925 |2 StatID |b ADV ENERGY MATER : 2021 |d 2022-11-12 |
| 920 | 1 | _ | |0 I:(DE-Juel1)IEK-12-20141217 |k IEK-12 |l Helmholtz-Institut Münster Ionenleiter für Energiespeicher |x 0 |
| 980 | 1 | _ | |a FullTexts |
| 980 | _ | _ | |a journal |
| 980 | _ | _ | |a VDB |
| 980 | _ | _ | |a UNRESTRICTED |
| 980 | _ | _ | |a I:(DE-Juel1)IEK-12-20141217 |
| 981 | _ | _ | |a I:(DE-Juel1)IMD-4-20141217 |
| Library | Collection | CLSMajor | CLSMinor | Language | Author |
|---|