% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@ARTICLE{Li:907132,
      author       = {Li, Xinfang and Groß-Barsnick, Sonja M. and Koppitz,
                      Thomas and Baumann, Stefan and Meulenberg, Wilhelm A. and
                      Natour, Ghaleb},
      title        = {{S}ealing behaviour of glass-based composites for oxygen
                      transport membranes},
      journal      = {Journal of the European Ceramic Society},
      volume       = {42},
      number       = {6},
      issn         = {0955-2219},
      address      = {Amsterdam [u.a.]},
      publisher    = {Elsevier Science},
      reportid     = {FZJ-2022-01859},
      pages        = {2879 - 2891},
      year         = {2022},
      abstract     = {In this study, seven different filler materials in
                      different proportions were added to a Ba-Ca-Si glass matrix
                      “H” to investigate new sealant with higher thermal
                      expansion coefficient (CTE) value and good sealing
                      performance for application in oxygen transport membrane
                      (OTM). SrTi0.75Fe0.25O3-δ (STF25) was used as an OTM, and
                      the sealing partners were ferritic steel Aluchrom and
                      pre-oxidized Aluchrom. Compatibility tests were carried out
                      to investigate the feasibility of the composites. Higher CTE
                      values were found in dilatometer tests on composite samples
                      by adding 40 $wt\%$ Ag (HAg40) and 30 $wt\%$ Ni-Cr (HNC30).
                      Gas-tightness measurements of sandwiched samples produced
                      appropriate helium leakage rates in the range of 10−6
                      mbar·l·s−1. Sealing behaviour of sealants HAg40 and
                      HNC30 were investigated by joining STF25 and
                      as-delivered/pre-oxidized Aluchrom together. Scanning
                      electron microscopy (SEM) on cross-sections of the joints
                      revealed a homogeneous microstructure and good adherence of
                      the glass sealants to support metals and STF25.},
      cin          = {IEK-1 / ZEA-1},
      ddc          = {660},
      cid          = {I:(DE-Juel1)IEK-1-20101013 / I:(DE-Juel1)ZEA-1-20090406},
      pnm          = {1232 - Power-based Fuels and Chemicals (POF4-123)},
      pid          = {G:(DE-HGF)POF4-1232},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:000766625000001},
      doi          = {10.1016/j.jeurceramsoc.2022.01.052},
      url          = {https://juser.fz-juelich.de/record/907132},
}