001     908204
005     20220621190117.0
024 7 _ |a 10.1109/NSSMIC.2018.8824431
|2 doi
037 _ _ |a FZJ-2022-02455
100 1 _ |a Xu, Hancong
|0 P:(DE-Juel1)168272
|b 0
111 2 _ |a 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
|c Sydney
|d 2018-11-10 - 2018-11-17
|w Australia
245 _ _ |a RESampling between Projection SpACEs (RESPACE) using Bayse’ Theorem
260 _ _ |c 2018
336 7 _ |a Abstract
|b abstract
|m abstract
|0 PUB:(DE-HGF)1
|s 1655804407_15481
|2 PUB:(DE-HGF)
336 7 _ |a Conference Paper
|0 33
|2 EndNote
336 7 _ |a INPROCEEDINGS
|2 BibTeX
336 7 _ |a conferenceObject
|2 DRIVER
336 7 _ |a Output Types/Conference Abstract
|2 DataCite
336 7 _ |a OTHER
|2 ORCID
520 _ _ |a Abstract:In order to simplify the Point-Spread-Function (PSF) reconstruction framework, resolution modelling can be decoupled from the iterative reconstruction process by an additional data resampling step previous to reconstruction. We call the proposed algorithm RESampling between Projection spACEs (RESPACE). In this abstract, RESPACE is applied to resample the simulated projection data to 2D Generic Cylinder Model (GCM) projection data structure, which will be used for reconstruction afterwards. Theoretically, the proposed algorithm merges pre-calculated detection probability information and prior information into the resampled projection data by applying Bayes' Theorem. In contrast to conventional projection data handling, RESPACE can make the iterative reconstruction isolated from any detection model or PSF modelling, ensuring the closed structure of normal non-PSF iterative algorithms. In this study, we implemented a 2D-PET simulation Monte Carlo framework, which has the same geometrical property as Siemens BrainPET transverse structure. Conventional MLEM, MLEM-PSF (both image space and projection space with shift-invariant kernel) and RESPACE are implemented and investigated. As figures of merit, Bias-Resolution curves demonstrate that RESPACE could achieve similar resolution and even better bias suppression performance as the PSF method with a shift-invariant kernel. Moreover, no significant visual difference is observed between images from PSF and RESPACE reconstruction. These results demonstrate that RESAPCE offers equivalent performance as the shift-invariant PSF method and this approach is an alternative resolution modelling method independent from the iterative reconstruction algorithm.
536 _ _ |a 5253 - Neuroimaging (POF4-525)
|0 G:(DE-HGF)POF4-5253
|c POF4-525
|f POF IV
|x 0
588 _ _ |a Dataset connected to CrossRef Conference
700 1 _ |a Scheins, Jurgen
|0 P:(DE-Juel1)131791
|b 1
|u fzj
700 1 _ |a Lerche, Christoph
|0 P:(DE-Juel1)164254
|b 2
|u fzj
700 1 _ |a Shah, N. J.
|0 P:(DE-Juel1)131794
|b 3
|u fzj
773 _ _ |a 10.1109/NSSMIC.2018.8824431
909 C O |o oai:juser.fz-juelich.de:908204
|p VDB
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 1
|6 P:(DE-Juel1)131791
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)164254
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)131794
913 1 _ |a DE-HGF
|b Key Technologies
|l Natural, Artificial and Cognitive Information Processing
|1 G:(DE-HGF)POF4-520
|0 G:(DE-HGF)POF4-525
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-500
|4 G:(DE-HGF)POF
|v Decoding Brain Organization and Dysfunction
|9 G:(DE-HGF)POF4-5253
|x 0
920 1 _ |0 I:(DE-Juel1)INM-4-20090406
|k INM-4
|l Physik der Medizinischen Bildgebung
|x 0
920 1 _ |0 I:(DE-Juel1)INM-11-20170113
|k INM-11
|l Jara-Institut Quantum Information
|x 1
920 1 _ |0 I:(DE-Juel1)VDB1046
|k JARA-BRAIN
|l Jülich-Aachen Research Alliance - Translational Brain Medicine
|x 2
980 _ _ |a abstract
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)INM-4-20090406
980 _ _ |a I:(DE-Juel1)INM-11-20170113
980 _ _ |a I:(DE-Juel1)VDB1046
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21