000908267 001__ 908267
000908267 005__ 20230123110628.0
000908267 0247_ $$2doi$$a10.1088/1361-6498/ac7916
000908267 0247_ $$2ISSN$$a0260-2814
000908267 0247_ $$2ISSN$$a0952-4746
000908267 0247_ $$2ISSN$$a1361-6498
000908267 0247_ $$2ISSN$$a1747-390X
000908267 0247_ $$2Handle$$a2128/31578
000908267 0247_ $$2pmid$$a35705007
000908267 0247_ $$2WOS$$aWOS:000818550200001
000908267 037__ $$aFZJ-2022-02501
000908267 082__ $$a530
000908267 1001_ $$0P:(DE-Juel1)137036$$aSchwan, Stefan$$b0
000908267 245__ $$aA software-based approach for calculating spatially resolved radiation exposure for structural radiation protection in nuclear medical imaging
000908267 260__ $$aBristol$$bIOP Publ.$$c2022
000908267 3367_ $$2DRIVER$$aarticle
000908267 3367_ $$2DataCite$$aOutput Types/Journal article
000908267 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1658916293_15902
000908267 3367_ $$2BibTeX$$aARTICLE
000908267 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000908267 3367_ $$00$$2EndNote$$aJournal Article
000908267 520__ $$aThe objective of the work described is the development of a software tool to provide the calculation routines for structural radiation protection from positron and gamma emitters, for example, 18F. The calculation of the generated local annual dose in the vicinity of these radioactive sources supports the engineering of structural measures necessary to meet regulatory guidelines. In addition to accuracy and precision, a visual and intuitive presentation of the calculation results enables fast evaluation. Finally, the calculated results are presented in a contour plot for design, evaluation, and documentation purposes. A python program was used to provide the calculation routines for structural radiation protection. For simplicity, the radiating sources can be considered as point sources. The attenuation of structural elements can be specified or, in the case of lead, calculated by virtue of its thickness. The calculated attenuation for the lead shielding is always slightly underestimated, which leads to a marginally higher calculated local dose rate than would be physically present. With the conservatively determined value, the structural radiation protection can be optimised in accordance with the general rule of as low as reasonably achievable. The pointwise comparison between the software results and the standard procedure for calculating the dose of points in space leads to similar values. In comparison with the general approach of calculating single representative points in the radiation protection area, the visual and intuitive presentation of the results supports the design and documentation of the measures required for structural radiation protection. In the present version of the software, the local dose rate and local annual dose are overestimated by a maximum of 4.5% in the case of lead shields. The proposed software, termed RadSoft, was successfully used to develop the structural radiation protection of a controlled area for hybrid magnetic resonance - positron emission tomography imaging, with the focus herein being on the requirements for PET.
000908267 536__ $$0G:(DE-HGF)POF4-5253$$a5253 - Neuroimaging (POF4-525)$$cPOF4-525$$fPOF IV$$x0
000908267 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
000908267 7001_ $$0P:(DE-Juel1)156522$$aKhezami, Arbia$$b1$$ufzj
000908267 7001_ $$0P:(DE-Juel1)173600$$aHohnholz, Janina$$b2$$ufzj
000908267 7001_ $$0P:(DE-Juel1)164254$$aLerche, Christoph W$$b3
000908267 7001_ $$0P:(DE-Juel1)131794$$aShah, N. J.$$b4$$eCorresponding author$$ufzj
000908267 773__ $$0PERI:(DE-600)2010389-X$$a10.1088/1361-6498/ac7916$$n2$$p021531$$tJournal of radiological protection$$v42$$x0260-2814$$y2022
000908267 8564_ $$uhttps://juser.fz-juelich.de/record/908267/files/Schwan_2022_J._Radiol._Prot._42_021531-1.pdf$$yOpenAccess
000908267 8767_ $$d2022-07-22$$eHybrid-OA$$jPublish and Read
000908267 909CO $$ooai:juser.fz-juelich.de:908267$$pdnbdelivery$$popenCost$$pVDB$$pdriver$$popen_access$$popenaire
000908267 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)137036$$aForschungszentrum Jülich$$b0$$kFZJ
000908267 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)156522$$aForschungszentrum Jülich$$b1$$kFZJ
000908267 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)173600$$aForschungszentrum Jülich$$b2$$kFZJ
000908267 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)164254$$aForschungszentrum Jülich$$b3$$kFZJ
000908267 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)131794$$aForschungszentrum Jülich$$b4$$kFZJ
000908267 9131_ $$0G:(DE-HGF)POF4-525$$1G:(DE-HGF)POF4-520$$2G:(DE-HGF)POF4-500$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-5253$$aDE-HGF$$bKey Technologies$$lNatural, Artificial and Cognitive Information Processing$$vDecoding Brain Organization and Dysfunction$$x0
000908267 9141_ $$y2022
000908267 915__ $$0StatID:(DE-HGF)1190$$2StatID$$aDBCoverage$$bBiological Abstracts$$d2021-01-30
000908267 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2021-01-30
000908267 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000908267 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2021-01-30
000908267 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000908267 915__ $$0StatID:(DE-HGF)0430$$2StatID$$aNational-Konsortium$$d2022-11-08$$wger
000908267 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bJ RADIOL PROT : 2021$$d2022-11-08
000908267 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2022-11-08
000908267 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2022-11-08
000908267 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2022-11-08
000908267 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2022-11-08
000908267 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2022-11-08
000908267 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2022-11-08
000908267 915__ $$0StatID:(DE-HGF)1050$$2StatID$$aDBCoverage$$bBIOSIS Previews$$d2022-11-08
000908267 915__ $$0StatID:(DE-HGF)1060$$2StatID$$aDBCoverage$$bCurrent Contents - Agriculture, Biology and Environmental Sciences$$d2022-11-08
000908267 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2022-11-08
000908267 9201_ $$0I:(DE-Juel1)INM-4-20090406$$kINM-4$$lPhysik der Medizinischen Bildgebung$$x0
000908267 9201_ $$0I:(DE-Juel1)INM-11-20170113$$kINM-11$$lJara-Institut Quantum Information$$x1
000908267 9201_ $$0I:(DE-Juel1)VDB1046$$kJARA-BRAIN$$lJülich-Aachen Research Alliance - Translational Brain Medicine$$x2
000908267 980__ $$ajournal
000908267 980__ $$aVDB
000908267 980__ $$aUNRESTRICTED
000908267 980__ $$aI:(DE-Juel1)INM-4-20090406
000908267 980__ $$aI:(DE-Juel1)INM-11-20170113
000908267 980__ $$aI:(DE-Juel1)VDB1046
000908267 980__ $$aAPC
000908267 9801_ $$aAPC
000908267 9801_ $$aFullTexts