000908995 001__ 908995
000908995 005__ 20240712113029.0
000908995 0247_ $$2doi$$a10.1016/j.solmat.2022.111913
000908995 0247_ $$2ISSN$$a0927-0248
000908995 0247_ $$2ISSN$$a1879-3398
000908995 0247_ $$2Handle$$a2128/33630
000908995 0247_ $$2WOS$$aWOS:000862591400002
000908995 037__ $$aFZJ-2022-02937
000908995 082__ $$a620
000908995 1001_ $$0P:(DE-Juel1)176906$$aBuerhop-Lutz, Claudia$$b0$$eCorresponding author
000908995 245__ $$aInsulation resistance in relation to distribution of backsheet types in strings and inverters
000908995 260__ $$aAmsterdam [u.a.]$$bNH, Elsevier$$c2022
000908995 3367_ $$2DRIVER$$aarticle
000908995 3367_ $$2DataCite$$aOutput Types/Journal article
000908995 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1673940579_26809
000908995 3367_ $$2BibTeX$$aARTICLE
000908995 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000908995 3367_ $$00$$2EndNote$$aJournal Article
000908995 520__ $$aPolymers are essential for long-term green energy production by photovoltaics (PV). We created a unique dataset that links electrical performance data of 28,030 PV modules, combined into 1295 strings and 423 inverters with the identity of the backsheet (BS) materials of each of the tested modules. This dataset gives an insight into BS-versatility and resulting impact on the insulation resistance of strings and inverters. The BSs were analyzed using near infrared absorption spectroscopy (NIRA) plus visual inspection in the field. The insulation resistance (Riso) of selected modules and strings was measured on-site. Furthermore, reported ground impedance (GI) values were evaluated with respect to an inverter-specific threshold below which the inverters do not start operation. We differentiated seven BS-types, the three most frequent being polyamide (PA), fluorinated coating (FC), and polyvinylidene fluoride (PVDF). Although modules with PA show often BS cracking, the insulation resistance was above the threshold. Similar, the GI of inverters with modules with PVDF-BSs was high. Modules with FC-BSs feature generally low Riso–values on module-, string-, and on inverter level. Evaluating historic data reveals an increase in frequency of GI-values below the threshold for inverters connected to modules with exclusively FC-BSs. While inverters with modules having PA- or PVDF-BSs function as expected, inverters with modules having FC-BSs require maintenance to keep power yield on an acceptable level. The dataset collected in the present work highlights that the choice of BS-material of PV-modules is essential for reliable operation of PV power stations.
000908995 536__ $$0G:(DE-HGF)POF4-1212$$a1212 - Materials and Interfaces (POF4-121)$$cPOF4-121$$fPOF IV$$x0
000908995 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
000908995 7001_ $$0P:(DE-Juel1)176897$$aPickel, Tobias$$b1$$ufzj
000908995 7001_ $$0P:(DE-Juel1)178670$$aStroyuk, Oleksandr$$b2$$ufzj
000908995 7001_ $$0P:(DE-Juel1)177626$$aHauch, Jens$$b3$$ufzj
000908995 7001_ $$0P:(DE-Juel1)179536$$aPeters, Ian Marius$$b4$$ufzj
000908995 773__ $$0PERI:(DE-600)2012677-3$$a10.1016/j.solmat.2022.111913$$gVol. 246, p. 111913 -$$p111913$$tSolar energy materials & solar cells$$v246$$x0927-0248$$y2022
000908995 8564_ $$uhttps://juser.fz-juelich.de/record/908995/files/1-s2.0-S0927024822003336-main.pdf$$yRestricted
000908995 8564_ $$uhttps://juser.fz-juelich.de/record/908995/files/paper_siliconPV_2022_clean.docx$$yPublished on 2022-08-03. Available in OpenAccess from 2024-08-03.
000908995 909CO $$ooai:juser.fz-juelich.de:908995$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000908995 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)176906$$aForschungszentrum Jülich$$b0$$kFZJ
000908995 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)176897$$aForschungszentrum Jülich$$b1$$kFZJ
000908995 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)178670$$aForschungszentrum Jülich$$b2$$kFZJ
000908995 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)177626$$aForschungszentrum Jülich$$b3$$kFZJ
000908995 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)179536$$aForschungszentrum Jülich$$b4$$kFZJ
000908995 9131_ $$0G:(DE-HGF)POF4-121$$1G:(DE-HGF)POF4-120$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1212$$aDE-HGF$$bForschungsbereich Energie$$lMaterialien und Technologien für die Energiewende (MTET)$$vPhotovoltaik und Windenergie$$x0
000908995 9141_ $$y2022
000908995 915__ $$0LIC:(DE-HGF)CCBYNCND4$$2HGFVOC$$aCreative Commons Attribution-NonCommercial-NoDerivs CC BY-NC-ND 4.0
000908995 915__ $$0StatID:(DE-HGF)0530$$2StatID$$aEmbargoed OpenAccess
000908995 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2021-02-02
000908995 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2021-02-02
000908995 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bSOL ENERG MAT SOL C : 2021$$d2022-11-25
000908995 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2022-11-25
000908995 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2022-11-25
000908995 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2022-11-25
000908995 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2022-11-25
000908995 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2022-11-25
000908995 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2022-11-25
000908995 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2022-11-25
000908995 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences$$d2022-11-25
000908995 915__ $$0StatID:(DE-HGF)9905$$2StatID$$aIF >= 5$$bSOL ENERG MAT SOL C : 2021$$d2022-11-25
000908995 920__ $$lyes
000908995 9201_ $$0I:(DE-Juel1)IEK-11-20140314$$kIEK-11$$lHelmholtz-Institut Erlangen-Nürnberg Erneuerbare Energien$$x0
000908995 9801_ $$aFullTexts
000908995 980__ $$ajournal
000908995 980__ $$aVDB
000908995 980__ $$aUNRESTRICTED
000908995 980__ $$aI:(DE-Juel1)IEK-11-20140314
000908995 981__ $$aI:(DE-Juel1)IET-2-20140314