TY - JOUR
AU - Pourshahidi, Ali Mohammad
AU - Achtsnicht, Stefan
AU - Offenhäusser, Andreas
AU - Krause, Hans-Joachim
TI - Frequency Mixing Magnetic Detection Setup Employing Permanent Ring Magnets as a Static Offset Field Source
JO - Sensors
VL - 22
IS - 22
SN - 1424-8220
CY - Basel
PB - MDPI
M1 - FZJ-2022-05178
SP - 8776 -
PY - 2022
AB - Frequency mixing magnetic detection (FMMD) has been explored for its applications in fields of magnetic biosensing, multiplex detection of magnetic nanoparticles (MNP) and the determination of core size distribution of MNP samples. Such applications rely on the application of a static offset magnetic field, which is generated traditionally with an electromagnet. Such a setup requires a current source, as well as passive or active cooling strategies, which directly sets a limitation based on the portability aspect that is desired for point of care (POC) monitoring applications. In this work, a measurement head is introduced that involves the utilization of two ring-shaped permanent magnets to generate a static offset magnetic field. A steel cylinder in the ring bores homogenizes the field. By variation of the distance between the ring magnets and of the thickness of the steel cylinder, the magnitude of the magnetic field at the sample position can be adjusted. Furthermore, the measurement setup is compared to the electromagnet offset module based on measured signals and temperature behavior.
LB - PUB:(DE-HGF)16
C6 - 36433383
UR - <Go to ISI:>//WOS:000887644400001
DO - DOI:10.3390/s22228776
UR - https://juser.fz-juelich.de/record/911931
ER -