000912067 001__ 912067
000912067 005__ 20240712112957.0
000912067 0247_ $$2doi$$a10.1103/PhysRevFluids.7.043901
000912067 0247_ $$2ISSN$$a2469-990X
000912067 0247_ $$2ISSN$$a2469-9918
000912067 0247_ $$2Handle$$a2128/34010
000912067 0247_ $$2WOS$$aWOS:000789342700003
000912067 037__ $$aFZJ-2022-05294
000912067 041__ $$aEnglish
000912067 082__ $$a530
000912067 1001_ $$0P:(DE-HGF)0$$aPhilippi, Julien$$b0$$eCorresponding author
000912067 245__ $$aLinear stability analysis of nonisothermal glass fiber drawing
000912067 260__ $$aCollege Park, MD$$bAPS$$c2022
000912067 3367_ $$2DRIVER$$aarticle
000912067 3367_ $$2DataCite$$aOutput Types/Journal article
000912067 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1677504387_26873
000912067 3367_ $$2BibTeX$$aARTICLE
000912067 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000912067 3367_ $$00$$2EndNote$$aJournal Article
000912067 520__ $$aThe draw resonance effect appears in fiber drawing processes when the draw ratio,defined as the ratio between the take-up and the inlet velocities, exceeds a critical value.In many cases, inertia, gravity, and surface tension cannot be neglected, and a modelcombining all these effects is necessary in order to correctly describe the physics of thephenomenon. Additionally, it is also known that cooling can have a highly stabilizing effecton the draw resonance instability. However, a detailed analysis encompassing the effect ofinertia, gravity, surface tension, and temperature is still lacking. Due to a destabilizingeffect induced by geometry in the heat equation, we first show that the maximum criticaldraw ratio for fiber drawing can be two orders of magnitude lower than the one for the filmcasting problem when the heat transfer coefficient is assumed constant. By introducing ascaling making the fiber aspect ratio an independent parameter, we next show that the highvalue of the critical draw ratio encountered in industrial applications could be rationalizedonly if we consider that the heat transfer coefficient is not constant but depends on boththe velocity and the cross-section area of the fiber. Within this framework, we show howthe practical stability window is affected by the five control parameters: the draw ratio,the fiber aspect ratio, the inlet temperature, the convective heat transfer coefficient, and thestiffness of the non-homogeneous ambient temperature. We finally discuss the influence ofradiative heat transfer on the stability.
000912067 536__ $$0G:(DE-HGF)POF4-1215$$a1215 - Simulations, Theory, Optics, and Analytics (STOA) (POF4-121)$$cPOF4-121$$fPOF IV$$x0
000912067 536__ $$0G:(GEPRIS)416229255$$aDFG project 416229255 - SFB 1411: Produktgestaltung disperser Systeme $$c416229255$$x1
000912067 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
000912067 7001_ $$0P:(DE-Juel1)179005$$aBechert, Mathias$$b1
000912067 7001_ $$0P:(DE-HGF)0$$aChouffart, Quentin$$b2
000912067 7001_ $$0P:(DE-HGF)0$$aWaucquez, Christophe$$b3
000912067 7001_ $$0P:(DE-HGF)0$$aScheid, Benoit$$b4
000912067 773__ $$0PERI:(DE-600)2868596-9$$a10.1103/PhysRevFluids.7.043901$$gVol. 7, no. 4, p. 043901$$n4$$p043901$$tPhysical review fluids$$v7$$x2469-990X$$y2022
000912067 8564_ $$uhttps://juser.fz-juelich.de/record/912067/files/Linear%20stability%20analysis%20of%20nonisothermal%20glass%20fiber%20drawing.pdf$$yOpenAccess
000912067 909CO $$ooai:juser.fz-juelich.de:912067$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000912067 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)179005$$aForschungszentrum Jülich$$b1$$kFZJ
000912067 9131_ $$0G:(DE-HGF)POF4-121$$1G:(DE-HGF)POF4-120$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1215$$aDE-HGF$$bForschungsbereich Energie$$lMaterialien und Technologien für die Energiewende (MTET)$$vPhotovoltaik und Windenergie$$x0
000912067 9141_ $$y2022
000912067 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2021-01-30
000912067 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2021-01-30
000912067 915__ $$0LIC:(DE-HGF)APS-112012$$2HGFVOC$$aAmerican Physical Society Transfer of Copyright Agreement
000912067 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bPHYS REV FLUIDS : 2019$$d2021-01-30
000912067 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2021-01-30
000912067 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2021-01-30
000912067 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2021-01-30
000912067 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000912067 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences$$d2021-01-30
000912067 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2021-01-30
000912067 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2021-01-30
000912067 920__ $$lyes
000912067 9201_ $$0I:(DE-Juel1)IEK-11-20140314$$kIEK-11$$lHelmholtz-Institut Erlangen-Nürnberg Erneuerbare Energien$$x0
000912067 9801_ $$aFullTexts
000912067 980__ $$ajournal
000912067 980__ $$aVDB
000912067 980__ $$aUNRESTRICTED
000912067 980__ $$aI:(DE-Juel1)IEK-11-20140314
000912067 981__ $$aI:(DE-Juel1)IET-2-20140314