000917485 001__ 917485
000917485 005__ 20240712084624.0
000917485 0247_ $$2Handle$$a2128/33626
000917485 037__ $$aFZJ-2023-00698
000917485 1001_ $$0P:(DE-HGF)0$$aBonomi, Germano$$b0$$eCorresponding author
000917485 1112_ $$aIAEA Symposium on International Safeguards$$cVienna$$d2022-10-31 - 2022-11-04$$wAustria
000917485 245__ $$aMUTOMCA: AN EXPERIMENT TO INVESTIGATE SPENT FUEL CASKS WITH MUON TOMOGRAPHY
000917485 260__ $$c2022
000917485 300__ $$a1-8
000917485 3367_ $$2ORCID$$aCONFERENCE_PAPER
000917485 3367_ $$033$$2EndNote$$aConference Paper
000917485 3367_ $$2BibTeX$$aINPROCEEDINGS
000917485 3367_ $$2DRIVER$$aconferenceObject
000917485 3367_ $$2DataCite$$aOutput Types/Conference Paper
000917485 3367_ $$0PUB:(DE-HGF)8$$2PUB:(DE-HGF)$$aContribution to a conference proceedings$$bcontrib$$mcontrib$$s1673936592_13094
000917485 520__ $$aSpent fuel stored in thick-walled strongly shielding casks can be indirectly verified through the application ofcontainment and surveillance measures. Assuring Continuity of Knowledge (CoK) of the spent fuel stored in dry spent fuelstorage facilities (SFSFs) for the upcoming decades is a cornerstone of safeguards. In the unlikely event that all Safeguardsrelatedcontainment and surveillance measures fail, a cask would need to be opened in the loading pond of a reactor. Therefore,substantially improved re-verification capabilities applicable to dry SFSFs are to be aimed at. The development of an adequatenon-destructive (re)-verification method for casks, proving the unchanged inventory of the verified spent fuel, would be a realadvantage for safeguards.Muon tomography could be a suitable method for the re-verification of self-shielding thick-walled spent fuel casks.To prove that the technology can detect the diversion of fuel assemblies, a two-modules muon detector has been designed andbuilt. It will be installed in the proximity of a spent fuel cask during a field test at a dry SFSF in Germany. The status of theproject and preliminary results will be presented.
000917485 536__ $$0G:(DE-HGF)POF4-1411$$a1411 - Nuclear Waste Disposal (POF4-141)$$cPOF4-141$$fPOF IV$$x0
000917485 536__ $$0G:(BMWi)02W6279$$aNeu- und Weiterentwicklung von Konzepten, Methoden und Techniken für die internationale Kernmaterialüberwachung, insbesondere im Rahmen der nuklearen Entsorgung (SAFEGUARDS-3) (02W6279)$$c02W6279$$x1
000917485 7001_ $$0P:(DE-HGF)0$$aAndretto, Paolo$$b1
000917485 7001_ $$0P:(DE-HGF)0$$aBenettoni, Massimo$$b2
000917485 7001_ $$0P:(DE-HGF)0$$aChecchia, Paolo$$b3
000917485 7001_ $$0P:(DE-HGF)0$$aGonella, Franco$$b4
000917485 7001_ $$0P:(DE-HGF)0$$aLorenzon, Altea$$b5
000917485 7001_ $$0P:(DE-HGF)0$$aZumerle, Gianni$$b6
000917485 7001_ $$0P:(DE-HGF)0$$aJussofie, Astrid$$b7
000917485 7001_ $$0P:(DE-HGF)0$$aBalling, Markus$$b8
000917485 7001_ $$0P:(DE-Juel1)130315$$aAymanns, Katharina$$b9$$ufzj
000917485 7001_ $$0P:(DE-Juel1)140251$$aNiemeyer, Irmgard$$b10$$ufzj
000917485 7001_ $$0P:(DE-HGF)0$$aAncius, Darius$$b11
000917485 7001_ $$0P:(DE-HGF)0$$aMurtezi, Mentor$$b12
000917485 8564_ $$uhttps://juser.fz-juelich.de/record/917485/files/Paper%20MUTOMCA%20Project.pdf$$yOpenAccess
000917485 909CO $$ooai:juser.fz-juelich.de:917485$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000917485 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130315$$aForschungszentrum Jülich$$b9$$kFZJ
000917485 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)140251$$aForschungszentrum Jülich$$b10$$kFZJ
000917485 9131_ $$0G:(DE-HGF)POF4-141$$1G:(DE-HGF)POF4-140$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1411$$aDE-HGF$$bForschungsbereich Energie$$lNukleare Entsorgung, Sicherheit und Strahlenforschung (NUSAFE II)$$vNukleare Entsorgung$$x0
000917485 9141_ $$y2022
000917485 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000917485 920__ $$lyes
000917485 9201_ $$0I:(DE-Juel1)IEK-6-20101013$$kIEK-6$$lNukleare Entsorgung$$x0
000917485 9801_ $$aFullTexts
000917485 980__ $$acontrib
000917485 980__ $$aVDB
000917485 980__ $$aUNRESTRICTED
000917485 980__ $$aI:(DE-Juel1)IEK-6-20101013
000917485 981__ $$aI:(DE-Juel1)IFN-2-20101013