000996727 001__ 996727
000996727 005__ 20240712113116.0
000996727 0247_ $$2doi$$a10.1016/j.apenergy.2022.120395
000996727 0247_ $$2ISSN$$a0306-2619
000996727 0247_ $$2ISSN$$a1872-9118
000996727 0247_ $$2Handle$$a2128/34063
000996727 0247_ $$2WOS$$aWOS:000909829500001
000996727 037__ $$aFZJ-2023-01147
000996727 082__ $$a620
000996727 1001_ $$00000-0002-7819-3223$$aHildenbrand, Felix$$b0$$eCorresponding author
000996727 245__ $$aInfluence of the anode overhang on the open-circuit voltage and the ageing of lithium-ion batteries—A model based study
000996727 260__ $$aAmsterdam [u.a.]$$bElsevier Science$$c2023
000996727 3367_ $$2DRIVER$$aarticle
000996727 3367_ $$2DataCite$$aOutput Types/Journal article
000996727 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1677848923_10334
000996727 3367_ $$2BibTeX$$aARTICLE
000996727 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000996727 3367_ $$00$$2EndNote$$aJournal Article
000996727 520__ $$aThe anode overhang has been proven to be a non-negligible influencing factor in the ageing trajectory of lithium-ion batteries. It acts through the transfer of active lithium between the anode overhang and the active anode by changing reversibly the cell balancing. In this work, the anode overhang is proven to influence the open-circuit voltage. Through a high-precision measurement, a persistent rise of the open-circuit voltage was observed, which we have demonstrated to originate in the anode overhang effect. The dimensions and structure of the anode overhang were verified by a post-mortem analysis of the cell and matched with the voltage behaviour. Derived from this finding, an existing electrical–thermal ageing model was extended to allow the simulation of the interaction between the anode overhang and the capacity. With a Bayesian optimisation approach, the extended model allowed to drastically improve model parametrisation when ageing test data include an increase in capacity. The resulting model was verified with the simulation of two ageing profiles, each including varying ageing conditions and phases of capacity recovery. The model allows ageing predictions with a deviation below 4% of the remaining capacity after more than 750 days of ageing. The model is publicly available as part of an open-source project.
000996727 536__ $$0G:(DE-HGF)POF4-1223$$a1223 - Batteries in Application (POF4-122)$$cPOF4-122$$fPOF IV$$x0
000996727 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
000996727 7001_ $$00000-0002-0860-7910$$aDitscheid, Dominik$$b1
000996727 7001_ $$0P:(DE-Juel1)191290$$aBarbers, Elias$$b2
000996727 7001_ $$0P:(DE-Juel1)172625$$aSauer, Dirk Uwe$$b3
000996727 773__ $$0PERI:(DE-600)2000772-3$$a10.1016/j.apenergy.2022.120395$$gVol. 332, p. 120395 -$$p120395$$tApplied energy$$v332$$x0306-2619$$y2023
000996727 8564_ $$uhttps://juser.fz-juelich.de/record/996727/files/1-s2.0-S030626192201652X-main.pdf$$yOpenAccess
000996727 909CO $$ooai:juser.fz-juelich.de:996727$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000996727 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)191290$$aForschungszentrum Jülich$$b2$$kFZJ
000996727 9131_ $$0G:(DE-HGF)POF4-122$$1G:(DE-HGF)POF4-120$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1223$$aDE-HGF$$bForschungsbereich Energie$$lMaterialien und Technologien für die Energiewende (MTET)$$vElektrochemische Energiespeicherung$$x0
000996727 9141_ $$y2023
000996727 915__ $$0LIC:(DE-HGF)CCBYNCND4$$2HGFVOC$$aCreative Commons Attribution-NonCommercial-NoDerivs CC BY-NC-ND 4.0
000996727 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2022-11-18
000996727 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000996727 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2022-11-18
000996727 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bAPPL ENERG : 2022$$d2023-08-25
000996727 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2023-08-25
000996727 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2023-08-25
000996727 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2023-08-25
000996727 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2023-08-25
000996727 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2023-08-25
000996727 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2023-08-25
000996727 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2023-08-25
000996727 915__ $$0StatID:(DE-HGF)9910$$2StatID$$aIF >= 10$$bAPPL ENERG : 2022$$d2023-08-25
000996727 9201_ $$0I:(DE-Juel1)IEK-12-20141217$$kIEK-12$$lHelmholtz-Institut Münster Ionenleiter für Energiespeicher$$x0
000996727 9801_ $$aFullTexts
000996727 980__ $$ajournal
000996727 980__ $$aVDB
000996727 980__ $$aUNRESTRICTED
000996727 980__ $$aI:(DE-Juel1)IEK-12-20141217
000996727 981__ $$aI:(DE-Juel1)IMD-4-20141217