Contribution to a conference proceedings/Contribution to a book FZJ-2023-01643

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Comparison of Black and Transparent PMMA in the Cone Calorimeter

 ;  ;  ;  ;

2023
ASTM International 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959

Obtaining Data for Fire Growth Models
ASTM 42nd Symposium on Obtaining Data for Fire Growth Models, onlineonline, 14 Dec 2021 - 15 Dec 20212021-12-142021-12-15
100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959 : ASTM International 150 - 160 () [10.1520/STP164220210105]

This record in other databases:

Please use a persistent id in citations: doi:

Abstract: The cone calorimeter is one of the standard devices used to assess the flammability of polymers. Several publications have been made studying different types of polymers and different set-ups in this apparatus. Polymers come in different forms and colors. It is unknown, however, whether the color of a polymer influences its burning behavior in the cone calorimeter. The color of a sample influences the amount of absorbed and reemitted thermal radiation, emitted by the cone calorimeter. This contribution presents the effect of different sample colors by performing cone calorimeter experiments with both transparent and black polymethyl methacrylate (PMMA) plates. Experiments were performed for four different heat fluxes: 25 kW/m², 35kW/m², 50kW/m², and 75 kW/m². All tests were autoignition experiments and 6-mm-thick PMMA plates were used. The effect of sample color on autoignition time, heat release rate, and mass loss data as well as oxygen (O2), carbon monoxide (CO), and carbon dioxide (CO2) production was assessed. Black PMMA showed a higher heat release rate (HRR) in the beginning of the tests, whereas transparent PMMA has a higher peak HRR. The color of the samples does not seem to influence the ignition time.


Contributing Institute(s):
  1. Zivile Sicherheitsforschung (IAS-7)
Research Program(s):
  1. 5111 - Domain-Specific Simulation & Data Life Cycle Labs (SDLs) and Research Groups (POF4-511) (POF4-511)

Appears in the scientific report 2023
Click to display QR Code for this record

The record appears in these collections:
Document types > Events > Contributions to a conference proceedings
Document types > Books > Contribution to a book
Institute Collections > IAS > IAS-7
Workflow collections > Public records
Publications database

 Record created 2023-03-30, last modified 2023-04-19


Restricted:
Download fulltext PDF
External link:
Download fulltextFulltext
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)