001026504 001__ 1026504
001026504 005__ 20250204113856.0
001026504 0247_ $$2doi$$a10.1016/j.ijepes.2024.110014
001026504 0247_ $$2ISSN$$a0142-0615
001026504 0247_ $$2ISSN$$a1879-3517
001026504 0247_ $$2datacite_doi$$a10.34734/FZJ-2024-03446
001026504 0247_ $$2WOS$$aWOS:001239362400001
001026504 037__ $$aFZJ-2024-03446
001026504 082__ $$a620
001026504 1001_ $$0P:(DE-Juel1)180837$$aZhang, Junjie$$b0$$eCorresponding author$$ufzj
001026504 245__ $$aShifted frequency analysis based, faster-than-real-time simulation of power systems on graphics processing unit
001026504 260__ $$aAmsterdam [u.a.]$$bElsevier Science$$c2024
001026504 3367_ $$2DRIVER$$aarticle
001026504 3367_ $$2DataCite$$aOutput Types/Journal article
001026504 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1738315190_12723
001026504 3367_ $$2BibTeX$$aARTICLE
001026504 3367_ $$2ORCID$$aJOURNAL_ARTICLE
001026504 3367_ $$00$$2EndNote$$aJournal Article
001026504 520__ $$aIn this paper we present a scalable approach based on the latency-based linear multistep compound method to use graphic processing unit (GPU) to accelerate the power system simulations with electromagnetic transients.To balance between the computational load and accuracy, we modeled the power system using shifted frequency analysis. Then, to efficiently exploit the hardware, our computational approach is designed to utilize both data-parallel and task-parallel execution. In addition, a graph-based thread safety design is introduced to achieve high scalability in the paralleled component computations. Furthermore, our implementation introduces a translation layer for different heterogeneous computing frameworks during compile time, so that a wide range of GPU devices can be supported without losing performance. Finally, benchmark results show that our approach achieves faster-than-real-time capability for systems with hundreds to thousands of nodes.
001026504 536__ $$0G:(DE-HGF)POF4-1122$$a1122 - Design, Operation and Digitalization of the Future Energy Grids (POF4-112)$$cPOF4-112$$fPOF IV$$x0
001026504 536__ $$0G:(GEPRIS)450829162$$aDFG project G:(GEPRIS)450829162 - Raum-Zeit-parallele Simulation multimodale Energiesystemen (450829162)$$c450829162$$x1
001026504 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
001026504 7001_ $$0P:(DE-Juel1)187421$$aMittenbühler, Marcel$$b1
001026504 7001_ $$0P:(DE-Juel1)179029$$aBenigni, Andrea$$b2$$ufzj
001026504 773__ $$0PERI:(DE-600)2001425-9$$a10.1016/j.ijepes.2024.110014$$gVol. 159, p. 110014 -$$p110014 -$$tInternational journal of electrical power & energy systems$$v159$$x0142-0615$$y2024
001026504 8564_ $$uhttps://juser.fz-juelich.de/record/1026504/files/1-s2.0-S0142061524002357-main.pdf$$yOpenAccess
001026504 8767_ $$8E-2024-00549-b$$92024-08-22$$d2024-09-09$$eAPC$$jZahlung erfolgt
001026504 909CO $$ooai:juser.fz-juelich.de:1026504$$pdnbdelivery$$popenCost$$pVDB$$pdriver$$pOpenAPC$$popen_access$$popenaire
001026504 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)180837$$aForschungszentrum Jülich$$b0$$kFZJ
001026504 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)179029$$aForschungszentrum Jülich$$b2$$kFZJ
001026504 9131_ $$0G:(DE-HGF)POF4-112$$1G:(DE-HGF)POF4-110$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1122$$aDE-HGF$$bForschungsbereich Energie$$lEnergiesystemdesign (ESD)$$vDigitalisierung und Systemtechnik$$x0
001026504 9141_ $$y2024
001026504 915pc $$0PC:(DE-HGF)0000$$2APC$$aAPC keys set
001026504 915pc $$0PC:(DE-HGF)0001$$2APC$$aLocal Funding
001026504 915pc $$0PC:(DE-HGF)0002$$2APC$$aDFG OA Publikationskosten
001026504 915pc $$0PC:(DE-HGF)0125$$2APC$$aDEAL: Elsevier 09/01/2023
001026504 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
001026504 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2023-08-23
001026504 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
001026504 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2023-08-23
001026504 915__ $$0StatID:(DE-HGF)0501$$2StatID$$aDBCoverage$$bDOAJ Seal$$d2024-04-15T09:28:30Z
001026504 915__ $$0StatID:(DE-HGF)0500$$2StatID$$aDBCoverage$$bDOAJ$$d2024-04-15T09:28:30Z
001026504 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bDOAJ : Anonymous peer review$$d2024-04-15T09:28:30Z
001026504 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2024-12-18
001026504 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2024-12-18
001026504 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2024-12-18
001026504 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bINT J ELEC POWER : 2022$$d2024-12-18
001026504 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2024-12-18
001026504 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2024-12-18
001026504 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2024-12-18
001026504 915__ $$0StatID:(DE-HGF)9905$$2StatID$$aIF >= 5$$bINT J ELEC POWER : 2022$$d2024-12-18
001026504 920__ $$lyes
001026504 9201_ $$0I:(DE-Juel1)ICE-1-20170217$$kICE-1$$lModellierung von Energiesystemen$$x0
001026504 980__ $$ajournal
001026504 980__ $$aVDB
001026504 980__ $$aUNRESTRICTED
001026504 980__ $$aI:(DE-Juel1)ICE-1-20170217
001026504 980__ $$aAPC
001026504 9801_ $$aAPC
001026504 9801_ $$aFullTexts
001026504 981__ $$aI:(DE-Juel1)ICE-1-20170217