% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@MISC{Froning:1039501,
      author       = {Froning, Dieter and Shi, Yan and Janssen, Holger and
                      Lehnert, Werner},
      title        = {{L}oad changes of a polymer electrolyte fuel cell under
                      different operating conditions},
      publisher    = {Jülich DATA},
      reportid     = {datapubs-10934573064807680574-802923379638844440},
      year         = {2024},
      abstract     = {A lab scale polymer electrolyte fuel cell (PEFC) with a
                      power of 9 W and an active area of 17.64 cm² was operated
                      with $90\%$ humidity and a stoichiometry factor of two in
                      galvanostatic mode. Load cycles were applied to the PEFC,
                      and the dynamic voltages were monitored. During the
                      experiments shown in jump-run.zip, seven attributes of
                      operating conditions were varied. The experimental setup is
                      specified in detail by Shi [1]. The data files are according
                      to section 5.1 in [1]. The data files in the path jump-run/
                      contain terms like 0.x-yy, where 0.x is the upper level of
                      the load ramp, starting at 0.2 A cm-2, yy is a numbering of
                      the set of operating conditions, listed in the file
                      'ramp-up-Experimental setup of DoE methode.pdf'. The
                      parameters A to G are according to Table 5-1 in [1]. The
                      files in the path ramp-up/ contain experiments operated
                      under stepwise increasing electrical load as specified in
                      the file 'jump-dynamic-Experimental setup of dynamic DoE
                      methode.pdf'. The parameters A to G are according to Table
                      6-1 in [1]. Data with constant operating conditions and
                      different ramp characteristics are published by Froning and
                      et al. [2].},
      cin          = {IEK-14 / IET-4},
      cid          = {I:(DE-Juel1)IEK-14-20191129 / I:(DE-Juel1)IET-4-20191129},
      pnm          = {1231 - Electrochemistry for Hydrogen (POF4-123)},
      pid          = {G:(DE-HGF)POF4-1231},
      typ          = {PUB:(DE-HGF)32},
      doi          = {10.26165/juelich-data/mln4jx},
      url          = {https://juser.fz-juelich.de/record/1039501},
}