001     1046553
005     20260113204518.0
024 7 _ |a 10.18416/IJMPI.2025.2503005
|2 doi
037 _ _ |a FZJ-2025-03863
041 _ _ |a English
082 _ _ |a 500
100 1 _ |a Bikulov, Timur
|0 P:(DE-Juel1)190282
|b 0
|e Corresponding author
|u fzj
111 2 _ |a International Workshop on Magnetic Particle Imaging
|g IWMPI
|c Lübeck
|d 2025-03-17 - 2025-03-19
|w Germany
245 _ _ |a Dual-frequency MPS enables direct MNP size reconstruction: Verification with micromagnetic simulation dataInternational Journal on Magnetic Particle Imaging IJMPI
260 _ _ |a Lübeck
|c 2025
|b Infinite Science Publishing
336 7 _ |a article
|2 DRIVER
336 7 _ |a Contribution to a conference proceedings
|0 PUB:(DE-HGF)8
|2 PUB:(DE-HGF)
|m contrib
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1768316343_19290
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Magnetic Particle Spectroscopy (MPS) allows for direct characterization of magneto-physical properties of magnetic nanoparticles (MNP), which are widely researched as imaging tracers, biosensing units and therapeutic heating agents. All these applications rely primarily on the core size-dependent magnetic particle relaxation dynamics. Therefore, knowledge about core size of any MNP sample is crucial. Dual-frequency MPS increases the characterization potential by considering frequency mixing terms of the received signal of MNP, from which their sizes can be approximated. In this work, preliminary feasibility and interpretation of a proposed size reconstruction method is tested against precisely simulated input data from stochastically coupled Néel-Brownian relaxation modeling using Monte Carlo implementation.
536 _ _ |a 5241 - Molecular Information Processing in Cellular Systems (POF4-524)
|0 G:(DE-HGF)POF4-5241
|c POF4-524
|f POF IV
|x 0
588 _ _ |a Dataset connected to DataCite
650 _ 7 |a dual-frequency
|2 Other
650 _ 7 |a magnetic moment distribution
|2 Other
650 _ 7 |a Monte-Carlo
|2 Other
650 _ 7 |a nonlinear magnetization
|2 Other
700 1 _ |a Abbas, Mohamad-Bilal
|0 0009-0003-7043-8606
|b 1
700 1 _ |a Krause, Hans-Joachim
|0 P:(DE-Juel1)128697
|b 2
700 1 _ |a Offenhäusser, Andreas
|0 P:(DE-Juel1)128713
|b 3
700 1 _ |a Engelmann, Ulrich
|0 0000-0001-9250-1686
|b 4
773 _ _ |a 10.18416/IJMPI.2025.2503005
|0 PERI:(DE-600)2893231-6
|n 1
|p 2503005
|t International journal on magnetic particle imaging
|v 11
|y 2025
|x 2365-9033
856 4 _ |u https://juser.fz-juelich.de/record/1046553/files/Paper.pdf
|y Restricted
909 C O |o oai:juser.fz-juelich.de:1046553
|p VDB
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)190282
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)128697
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)128713
913 1 _ |a DE-HGF
|b Key Technologies
|l Natural, Artificial and Cognitive Information Processing
|1 G:(DE-HGF)POF4-520
|0 G:(DE-HGF)POF4-524
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-500
|4 G:(DE-HGF)POF
|v Molecular and Cellular Information Processing
|9 G:(DE-HGF)POF4-5241
|x 0
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2025-01-01
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2025-01-01
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)IBI-3-20200312
|k IBI-3
|l Bioelektronik
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a contrib
980 _ _ |a I:(DE-Juel1)IBI-3-20200312
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21