Poster (Invited) FZJ-2026-00554

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Eddy Current Mapping for In-line Quality Control of PEM Electrolyser Electrodes and MEAs

 ;  ;  ;  ;  ;

2025

H2giga Abschlusskonferenz, FrankfurtFrankfurt, Germany, 2 Jul 2025 - 3 Jul 20252025-07-022025-07-03

Abstract: In polymer electrolyte membrane (PEM) water electrolysis the activematerial component is the membrane electrode assembly (MEA)consisting of a cathode and an anode catalyst layer (CL) coated on aproton conducting membrane.During large-scale MEA production critical process steps are thetemperature treatment (tempering) of CLs and the CL decal transfer onto the membrane as they have a great impact on electrodeconductivity, which is an important factor in MEA performance.To monitor the quality of these production steps a fast and reliablein-line analysis tool needs to be established. This becomes especiallyimportant as the production volume is increasing towards the GWscale. Here, we propose the eddy current technique for in-linequality control. It is an inductive, non-destructive method andprovides fast and accurate sheet resistance information.

Keyword(s): Chemistry (2nd)


Contributing Institute(s):
  1. Grundlagen der Elektrochemie (IET-1)
Research Program(s):
  1. 1231 - Electrochemistry for Hydrogen (POF4-123) (POF4-123)

Click to display QR Code for this record

The record appears in these collections:
Document types > Presentations > Poster
Institute Collections > IET > IET-1
Workflow collections > Public records
Publications database

 Record created 2026-01-16, last modified 2026-01-19



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)