@INPROCEEDINGS{Bartoli:1051640,
author = {Bartoli, Francesco and Hilche, Tobias and Liu, Jialiang and
Karl, André and Jodat, Eva and Eichel, Rüdiger-A.},
title = {{E}ddy {C}urrent {M}apping for {I}n-line {Q}uality
{C}ontrol of {PEM} {E}lectrolyser {E}lectrodes and {MEA}s},
reportid = {FZJ-2026-00554},
year = {2025},
abstract = {In polymer electrolyte membrane (PEM) water electrolysis
the activematerial component is the membrane electrode
assembly (MEA)consisting of a cathode and an anode catalyst
layer (CL) coated on aproton conducting membrane.During
large-scale MEA production critical process steps are
thetemperature treatment (tempering) of CLs and the CL decal
transfer onto the membrane as they have a great impact on
electrodeconductivity, which is an important factor in MEA
performance.To monitor the quality of these production steps
a fast and reliablein-line analysis tool needs to be
established. This becomes especiallyimportant as the
production volume is increasing towards the GWscale. Here,
we propose the eddy current technique for in-linequality
control. It is an inductive, non-destructive method
andprovides fast and accurate sheet resistance information.},
month = {Jul},
date = {2025-07-02},
organization = {H2giga Abschlusskonferenz, Frankfurt
(Germany), 2 Jul 2025 - 3 Jul 2025},
subtyp = {Invited},
cin = {IET-1},
cid = {I:(DE-Juel1)IET-1-20110218},
pnm = {1231 - Electrochemistry for Hydrogen (POF4-123)},
pid = {G:(DE-HGF)POF4-1231},
typ = {PUB:(DE-HGF)24},
url = {https://juser.fz-juelich.de/record/1051640},
}