Abstract: Purpose: Quantitative brain studies with positron emission tomography (PET) often require an arterial input function (AIF), which traditionally requires arterial cannulation. However, this is invasive. An alternative, non-invasive method is to use the image-derived input function (IDIF) derived from the activity concentration in the internal carotid arteries (ICAs) in the images. To achieve an accurate IDIF, validation and optimization of IDIF estimations using phantoms with controlled methodological parameters are required. The goal of this study was to develop: 1) a geometrical phantom with ICA inserts as a reliable baseline for IDIF studies, and 2) an anthropomorphic head phantom with realistic anatomical features to enhance IDIF accuracy and expand validation applications.Methods: Phantom 1) was based on a combination of a cylindrical quality-control phantom already available in our institute [1] and an additional ICA insert [2]. Phantom 2), based on previous work [3], replicates the human head contour and brain anatomy. Segmentation of grey matter (GM), white matter (WM), and scalp was performed using 3D Slicer v5.4.0, combining manual and semi-automatic threshold methods. ICA structures were extracted from magnetic resonance angiography data and refined using CAD software. The GM, WM, and ICA compartments were designed as fillable hollow compartments.Results: Both 3D-printed phantoms include watertight compartments capable of holding different radiotracer concentrations and ICA dynamic simulations. The neck structure of the head phantom is extended to facilitate secure attachment to mechanical holders, enabling precise motion simulations during PET/MR studies.Conclusion: The cylindrical phantom with an ICA insert is currently in the printing phase and the head phantom is in the final development phase (equivalent tissue materials and printing tests). After successfully printing both phantoms, PET/MR acquisitions will be performed for testing and validation. The updated status of this work will be presented during the conference.


Contributing Institute(s):
  1. Physik der Medizinischen Bildgebung (INM-4)
Research Program(s):
  1. 5253 - Neuroimaging (POF4-525) (POF4-525)

Click to display QR Code for this record

The record appears in these collections:
Document types > Presentations > Poster
Institute Collections > INM > INM-4
Workflow collections > Public records
Publications database

 Record created 2026-01-30, last modified 2026-01-30


External link:
Download fulltext
Fulltext
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)