%0 Journal Article
%A Yazdanbakhsh, F.
%A Bläsing, Marc
%A Sawada, J.
%A Rezaei, S.
%A Müller, Michael
%A Baumann, Stefan
%T Copper Exchanged Nanotitanate for High Temperature H2S Adsorption
%J Industrial and engineering chemistry / Product research and development
%V 53
%@ 1541-4841
%C Easton, Pa.
%I Soc.
%M FZJ-2014-05161
%P 11734-11739
%D 2014
%X The H2S breakthrough capacity of copper-exchanged Engelhard Titanosilicate-2 (ETS-2) was measured attemperatures up to 950 °C and it was found that the adsorbent efficiency remains unchanged across the entire temperaturerange. Below 750 °C, the adsorption capacity at breakthrough is 0.7 mol of H2S per mole of copper while above 750 °C thecapacity of the adsorbent is halved. The change in H2S capacity is due to Cu2+ reduction by the H2 which is formed through thethermal dissociation of H2S. The adsorbent shows good potential for use over a wide range of operating temperatures in H2Sscrubbing processes.
%F PUB:(DE-HGF)16
%9 Journal Article
%U https://juser.fz-juelich.de/record/156418