Abstract: The H2S breakthrough capacity of copper-exchanged Engelhard Titanosilicate-2 (ETS-2) was measured attemperatures up to 950 °C and it was found that the adsorbent efficiency remains unchanged across the entire temperaturerange. Below 750 °C, the adsorption capacity at breakthrough is 0.7 mol of H2S per mole of copper while above 750 °C thecapacity of the adsorbent is halved. The change in H2S capacity is due to Cu2+ reduction by the H2 which is formed through thethermal dissociation of H2S. The adsorbent shows good potential for use over a wide range of operating temperatures in H2Sscrubbing processes.
![]() |