001     17746
005     20240711101525.0
024 7 _ |2 DOI
|a 10.1115/1.4006490
024 7 _ |2 WOS
|a WOS:000304819200011
037 _ _ |a PreJuSER-17746
041 _ _ |a eng
082 _ _ |a 620
084 _ _ |2 WoS
|a Electrochemistry
084 _ _ |2 WoS
|a Energy & Fuels
100 1 _ |0 P:(DE-Juel1)129888
|a Mergel, J.
|b 0
|u FZJ
245 _ _ |a Development of direct methanol fuel cell systems for material handling applications
260 _ _ |a New York, NY
|b ASME
|c 2012
300 _ _ |a 031011
336 7 _ |a Journal Article
|0 PUB:(DE-HGF)16
|2 PUB:(DE-HGF)
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|0 0
|2 EndNote
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a article
|2 DRIVER
440 _ 0 |0 12982
|a Journal of Fuel Cell Science and Technology
|v 9
|x 1550-624X
|y 3
500 _ _ |a The development was funded by the Federal Ministry of Economics and Technology (BMWi) as part of a collaborative project (reference nos. 0327769A und 0327769B).
520 _ _ |a Direct methanol fuel cells (DMFCs) are attractive for various applications, above all, however, as replacements for batteries or accumulators. They may be used in different power classes. A market analysis indicated that the use of a DMFC energy system in the kW class had the best chance of commercial realization if applied in forklift trucks for material handling in large distribution centers or warehouses. An advantage of such energy systems is that there is no need for the relatively time-consuming recharging of the lead-acid batteries, nor is it necessary to have spare batteries available for multishift operation. This calls for DMFC energy systems that are capable of replacing the existing Pb accumulators in terms of space requirements and energy. However, this requires considerable improvements to be made in terms of power and stability over time of DMFC systems and, in comparison to their present status, an increase of overall efficiency. Recent cost analyses for the overall system; for example, show that for the DMFC stack, a durability of at least 5000 h must be achieved with an overall efficiency for the DMFC system of at least 30%, with the constraint that the system can be operated in a water-autonomous manner up to an ambient temperature of 35 degrees C. As part of a joint R&D project with industrial partners, two systems were constructed and each subjected to long-term testing for 3000 and more than 8000 h, respectively, with realistic load profiles from driving cycles. In this test, the stack from the first system, DMFC V 3.3-1, displayed an aging rate of approximately 52 mu V h(-1) at a current density of 100 mA cm(-2). This corresponds to a performance degradation of 25% over a period of 3,000 h. The DMFC V 3.3-2 system, a modified and optimized version of the first system, also underwent long-term testing. In this case, the aging rate of the stack was only approximately 9 mu V h(-1) at a current density of 100 mA cm(-2). The system has thus been operated to date for more than 8000 h under realistic load profiles. [DOI:10.1115/1.4006490]
536 _ _ |0 G:(DE-Juel1)FUEK402
|2 G:(DE-HGF)
|a Rationelle Energieumwandlung
|c P12
|x 0
588 _ _ |a Dataset connected to Web of Science
650 _ 7 |2 WoSType
|a J
653 2 0 |2 Author
|a direct methanol fuel cell
653 2 0 |2 Author
|a material handling
653 2 0 |2 Author
|a hybridization
653 2 0 |2 Author
|a system
653 2 0 |2 Author
|a long term stability
653 2 0 |2 Author
|a forklift
700 1 _ |0 P:(DE-Juel1)129863
|a Janßen, H.
|b 1
|u FZJ
700 1 _ |0 P:(DE-Juel1)129892
|a Müller, M.
|b 2
|u FZJ
700 1 _ |0 P:(DE-Juel1)VDB69635
|a Wilhelm, J.
|b 3
|u FZJ
700 1 _ |0 P:(DE-Juel1)129928
|a Stolten, D.
|b 4
|u FZJ
773 _ _ |0 PERI:(DE-600)2166032-3
|a 10.1115/1.4006490
|g Vol. 9, p. 031011
|p 031011
|q 9<031011
|t Journal of fuel cell science and technology
|v 9
|x 1550-624X
|y 2012
856 7 _ |u http://dx.doi.org/10.1115/1.4006490
856 4 _ |u https://juser.fz-juelich.de/record/17746/files/FZJ-17746_PV.pdf
|z Published final document.
|y Restricted
909 C O |o oai:juser.fz-juelich.de:17746
|p VDB
913 1 _ |0 G:(DE-Juel1)FUEK402
|1 G:(DE-HGF)POF2-120
|2 G:(DE-HGF)POF2-100
|a DE-HGF
|b Energie
|k P12
|l Rationelle Energieumwandlung
|v Rationelle Energieumwandlung
|x 0
913 2 _ |0 G:(DE-HGF)POF3-135
|1 G:(DE-HGF)POF3-130
|2 G:(DE-HGF)POF3-100
|a DE-HGF
|b Forschungsbereich Energie
|l Speicher und vernetzte Infrastrukturen
|v Fuel Cells
|x 0
914 1 _ |y 2012
915 _ _ |0 StatID:(DE-HGF)0010
|2 StatID
|a JCR/ISI refereed
915 _ _ |0 StatID:(DE-HGF)0100
|2 StatID
|a JCR
915 _ _ |0 StatID:(DE-HGF)0111
|2 StatID
|a WoS
|b Science Citation Index Expanded
915 _ _ |0 StatID:(DE-HGF)0150
|2 StatID
|a DBCoverage
|b Web of Science Core Collection
915 _ _ |0 StatID:(DE-HGF)0199
|2 StatID
|a DBCoverage
|b Thomson Reuters Master Journal List
915 _ _ |0 StatID:(DE-HGF)0200
|2 StatID
|a DBCoverage
|b SCOPUS
915 _ _ |0 StatID:(DE-HGF)1040
|2 StatID
|a DBCoverage
|b Zoological Record
920 1 _ |0 I:(DE-Juel1)IEK-3-20101013
|g IEK
|k IEK-3
|l Brennstoffzellen
|x 0
970 _ _ |a VDB:(DE-Juel1)132311
980 _ _ |a VDB
980 _ _ |a ConvertedRecord
980 _ _ |a journal
980 _ _ |a I:(DE-Juel1)IEK-3-20101013
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)ICE-2-20101013


LibraryCollectionCLSMajorCLSMinorLanguageAuthor