Journal Article PreJuSER-17746

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Development of direct methanol fuel cell systems for material handling applications

 ;  ;  ;  ;

2012
ASME New York, NY

Journal of fuel cell science and technology 9, 031011 () [10.1115/1.4006490]

This record in other databases:  

Please use a persistent id in citations: doi:

Abstract: Direct methanol fuel cells (DMFCs) are attractive for various applications, above all, however, as replacements for batteries or accumulators. They may be used in different power classes. A market analysis indicated that the use of a DMFC energy system in the kW class had the best chance of commercial realization if applied in forklift trucks for material handling in large distribution centers or warehouses. An advantage of such energy systems is that there is no need for the relatively time-consuming recharging of the lead-acid batteries, nor is it necessary to have spare batteries available for multishift operation. This calls for DMFC energy systems that are capable of replacing the existing Pb accumulators in terms of space requirements and energy. However, this requires considerable improvements to be made in terms of power and stability over time of DMFC systems and, in comparison to their present status, an increase of overall efficiency. Recent cost analyses for the overall system; for example, show that for the DMFC stack, a durability of at least 5000 h must be achieved with an overall efficiency for the DMFC system of at least 30%, with the constraint that the system can be operated in a water-autonomous manner up to an ambient temperature of 35 degrees C. As part of a joint R&D project with industrial partners, two systems were constructed and each subjected to long-term testing for 3000 and more than 8000 h, respectively, with realistic load profiles from driving cycles. In this test, the stack from the first system, DMFC V 3.3-1, displayed an aging rate of approximately 52 mu V h(-1) at a current density of 100 mA cm(-2). This corresponds to a performance degradation of 25% over a period of 3,000 h. The DMFC V 3.3-2 system, a modified and optimized version of the first system, also underwent long-term testing. In this case, the aging rate of the stack was only approximately 9 mu V h(-1) at a current density of 100 mA cm(-2). The system has thus been operated to date for more than 8000 h under realistic load profiles. [DOI:10.1115/1.4006490]

Keyword(s): J ; direct methanol fuel cell (auto) ; material handling (auto) ; hybridization (auto) ; system (auto) ; long term stability (auto) ; forklift (auto)


Note: The development was funded by the Federal Ministry of Economics and Technology (BMWi) as part of a collaborative project (reference nos. 0327769A und 0327769B).

Contributing Institute(s):
  1. Brennstoffzellen (IEK-3)
Research Program(s):
  1. Rationelle Energieumwandlung (P12)

Appears in the scientific report 2012
Database coverage:
JCR ; SCOPUS ; Science Citation Index Expanded ; Thomson Reuters Master Journal List ; Web of Science Core Collection ; Zoological Record
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > ICE > ICE-2
Workflow collections > Public records
IEK > IEK-3
Publications database

 Record created 2012-11-13, last modified 2024-07-11


Restricted:
Download fulltext PDF
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)