| Home > Publications database > Water Vapour Distribution in HT-PEFC - A Pragmatical Approach for CFD Simulations |
| Abstract | FZJ-2015-01663 |
; ;
2015
Abstract: Abstract for poster presentationWater vapour distribution in HT-PEFC a pragmatical approach for CFD simulationsUwe Reimer*1, Dieter Froning1, Werner Lehnert1,21 Forschungszentrum Jülich GmbH, Institute of Energy and Climate Research, Electrochemical Process Engineering, 52425 Jülich, Germany2 Modeling in Electrochemical Process Engineering, RWTH Aachen University, Aachen, Germany*Presenting author, email: u.reimer@fz-juelich.de, Tel.: +49 2461-3537In polymer electrolyte fuel cells water is produced within the cathode catalyst layer. This water is leaving the fuel cell both through anode and cathode gas channel. The distribution of water to anode and cathode side is difficult to predict. It depends on material properties of membrane, catalyst layers, microporous layers and gas diffusion layers [1,2]. Additionally, the dynamics of evaporation and condensation which in turn are strongly influenced by flow configuration, local current density and local temperature have to be taken into account in order to obtain correct values for mass flow and local gas concentration in CFD simulations [1].For HT-PEFCs operated at 160 °C the produced water is in the gas state. Recently, a detailed model for vapour distribution was published [3]. In order to obtain a model with little computational demand a model for water distribution is developed. The basic assumption is that water evaporation is very fast and the final distribution between cathode and anode depends mainly on the mass flow in the gas channels. In order to reach the anode water has to pass through the membrane. This process is captured by including a resistance term in the model. This resistance term is fitted to experimental data. The fitted value for the resistance term is rather small at ‘normal’ operation conditions and leads to a difference of 10 % compared to the model which only considers the mass flow on anode and cathode. Therefore, the presented model might be a practical approach to include the effect of water vapour distribution to cathode and anode as a rough estimation. This is important because local current density and voltage are depending on correct values for local concentrations. The experiment was carried out with a HT-PEFC single cell with PBI/ phosphoric acid membrane operated at 160 °C and ambient pressure with air and hydrogen. The CFD model is based on a previously published one [4] with the extension of water distribution [5]. The flow field geometry is a threefold meander with an active area of 17 cm2.[1] A. Z. Weber, R. L. Borup, R. M. Darling, P. K. Das, T. J. Dursch, W. Gu, D. Harvey, A. Kusoglu, S. Litster, M. M. Mench, R. Mukundan, J. P. Owejan, J. G. Pharoah, M. Secanell and I. V. Zenyuk, J. Electrochem. Soc., 161 (2014), F1254 [2] A. Thomas, G. Maranzana, S. Didierjean, J. Dillet, O. Lottin, Int. J. Hydrogen Energy, 39 (2014), 2649[3] T. J. Kazdal, S. Lang, F. Kühl, M. J. Hampe, J. Power Sources, 249 (2014), 446[4] M. Kvesić, U. Reimer, W. Lehnert, D. Froning, L. Lüke, D. Stolten, Int. J. Hydrogen Energy, 37 (2012), 2430[5] A. Kind, Masterthesis, FH Aachen, Jülich/ Aachen, Germany (2014)
|
The record appears in these collections: |