% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@ARTICLE{Kichin:201032,
author = {Kichin, Georgy and Wagner, C. and Tautz, Frank Stefan and
Temirov, R.},
title = {{C}alibrating atomic-scale force sensors installed at the
tip apex of a scanning tunneling microscope},
journal = {Physical review / B},
volume = {87},
number = {8},
issn = {1098-0121},
address = {College Park, Md.},
publisher = {APS},
reportid = {FZJ-2015-03342},
pages = {081408},
year = {2013},
abstract = {Scanning tunneling microscopy (STM) tips decorated with
either a single carbon monoxide molecule or a single xenon
atom are characterized by simultaneous force and conductance
measurements using a combined low-temperature noncontact
atomic force and scanning tunneling microscope (NC-AFM/STM).
It is shown that in both cases the particle decorating the
tip simultaneously performs the function of an atomic-scale
force sensor and transducer which couples the short-range
force acting on the tip to the tunneling conductance of the
junction. On the basis of the experimental data, two
distinct coupling regimes are identified; in one of them the
force sensor-transducer function is calibrated
quantitatively.},
cin = {PGI-3},
ddc = {530},
cid = {I:(DE-Juel1)PGI-3-20110106},
pnm = {422 - Spin-based and quantum information (POF2-422)},
pid = {G:(DE-HGF)POF2-422},
typ = {PUB:(DE-HGF)16},
UT = {WOS:000315278000001},
doi = {10.1103/PhysRevB.87.081408},
url = {https://juser.fz-juelich.de/record/201032},
}