% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@ARTICLE{Blum:255665,
author = {Blum, Ludger and Batfalsky, P. and Fang, Qingping and
deHaart, L. G. J. and Malzbender, Jürgen and Margaritis,
Nikolaos and Menzler, Norbert H. and Peters, Roland},
title = {{SOFC} {S}tack and {S}ystem {D}evelopment at
{F}orschungszentrum {J}ülich},
journal = {Journal of the Electrochemical Society},
volume = {162},
number = {10},
issn = {0013-4651},
address = {Pennington, NJ},
publisher = {Electrochemical Soc.},
reportid = {FZJ-2015-05798},
pages = {F1199-F1205},
year = {2015},
abstract = {Long-term stable and robust stack technology is a
pre-requisite for a successful implementation of SOFC in the
market and so it is one of the main issues in SOFC
development. Also bigger stacks are desirable for systems
with increased power output. Progress in stack and systems
development is illustrated. Enhanced thermo-mechanical
robustness of stacks in the kW range was demonstrated by
successfully cycling a five layer stack incorporating cells
of 20 × 20 cm² 100 times between 200 and 700°C. Aiming at
the utilization of anode-supported cells from other
manufacturers, the design was modified to a window frame
layout, integrating in this case four 10 × 10 cm² cells in
one layer. A 20 kW system was operated for about 7000 hours
in total, thereby demonstrating the suitability of the
module and system concept. As special highlights, long-term
tests with short stacks have now reached operation times of
66,500 h and 34,500 h, respectively. As a relatively new
subject, activities entailed by high temperature
electrolysis are briefly outlined.},
cin = {IEK-1 / IEK-2 / IEK-3 / ZEA-1},
ddc = {540},
cid = {I:(DE-Juel1)IEK-1-20101013 / I:(DE-Juel1)IEK-2-20101013 /
I:(DE-Juel1)IEK-3-20101013 / I:(DE-Juel1)ZEA-1-20090406},
pnm = {135 - Fuel Cells (POF3-135)},
pid = {G:(DE-HGF)POF3-135},
typ = {PUB:(DE-HGF)16},
UT = {WOS:000361501800091},
doi = {10.1149/2.0491510jes},
url = {https://juser.fz-juelich.de/record/255665},
}