Dissertation / PhD Thesis/Book PreJuSER-35337

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Stochastische Algorithmen zur Parameterschätzung in der Kompaktmentanalyse von dynamischen Positronen-Emissions-Tomographischen Daten



1999
Forschungszentrum, Zentralbibliothek Jülich

Jülich : Forschungszentrum, Zentralbibliothek, Berichte des Forschungszentrums Jülich 3720, () = Aachen, Techn. Hochsch., Diss., 1999

Please use a persistent id in citations:

Report No.: Juel-3720

Abstract: Positron-Emission-Tomography (PET) is a modern medicine technology to gain information about the distribution of biochemical substances in the living human. The substances used for the examination are called tracers and show the metabolic behavior of the substance . The measurement is quantitative so that the dynamics of the metabolization can be calculated by recording a series of pictures. Because of the complex structure and limited spatial and temporal resolution of PET, simplifications have to be introduced to analyze the data . Biomathematical models are used to perform this task . The defmition of appropriate models and the estimation of related parameters is called modelling . Its goal is to extract relevant metabolic parameters showing differences in normal or diseased tissue. Models for PET data, especially the mainly used compartment models, are discussed in this paper. Different methods for parameter extraction, i .e. graphical and algebraic nonlinear algorithms, are described in detail. A common problem of the nonlinear parameter estimation is its dependence on starting values. Another problem is the uniqueness of the estimated parameters. These problems are addressed by two new algorithms . They are based on the stochastic approach of simulated annealing. Comparisons to conventional algorithms known from literature are given . The new algorithms show independence of starting values and a better numerical stability . Furthermore, they help with the identification of the parameters . In this way the proposed procedures are regarded as important for the development of new tracers and models.


Note: Record converted from VDB: 12.11.2012
Note: Aachen, Techn. Hochsch., Diss., 1999

Contributing Institute(s):
  1. Institut für Medizin (IME)
Research Program(s):
  1. ohne FE (ohne FE)

Appears in the scientific report 1999
Database coverage:
OpenAccess
Click to display QR Code for this record

The record appears in these collections:
Dokumenttypen > Hochschulschriften > Doktorarbeiten
Workflowsammlungen > Öffentliche Einträge
Publikationsdatenbank
Open Access
INB-3

 Datensatz erzeugt am 2012-11-13, letzte Änderung am 2020-06-10


Dieses Dokument bewerten:

Rate this document:
1
2
3
 
(Bisher nicht rezensiert)