000039769 1001_ $$0P:(DE-Juel1)VDB2188$$aBussmann, N.$$b0$$uFZJ
000039769 245__ $$aPerformance measurement of a new high-resolution detector system for I-131 thyroid studies
000039769 260__ $$aNew York, NY$$bIEEE$$c2001
000039769 300__ $$a625 - 627
000039769 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article
000039769 3367_ $$2DataCite$$aOutput Types/Journal article
000039769 3367_ $$00$$2EndNote$$aJournal Article
000039769 3367_ $$2BibTeX$$aARTICLE
000039769 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000039769 3367_ $$2DRIVER$$aarticle
000039769 440_0 $$02524$$aIEEE Transactions on Nuclear Science$$v48$$x0018-9499
000039769 500__ $$aRecord converted from VDB: 12.11.2012
000039769 520__ $$aA two-dimensional detector system for high-resolution thyroid I-131 scintigraphy was developed. It has a sensitive area of 4 x 4 cm(2) and consists of a lead collimator and an array of 10 x 10 BGO crystals combined with a position-sensitive photomultiplier. The spatial resolution and the sensitivity of the detector have been measured and compared to two commercially available gamma cameras. The full-width half-maximum for the new system is 3.8 mm. Furthermore, first patient measurements have been carried out.
000039769 536__ $$0G:(DE-Juel1)FUEK66$$2G:(DE-HGF)$$aIonen- und Lithographietechnik$$c29.86.0$$x0
000039769 536__ $$0G:(DE-Juel1)FUEK101$$aOn-Line-Datenverarbeitung$$c52.20.0$$x1
000039769 536__ $$0G:(DE-Juel1)FUEK89$$aSignaltransduktion$$c40.10.0$$x2
000039769 588__ $$aDataset connected to Web of Science
000039769 650_7 $$2WoSType$$aJ
000039769 65320 $$2Author$$adetectors
000039769 65320 $$2Author$$aI-131
000039769 65320 $$2Author$$ascintigraphy
000039769 65320 $$2Author$$athyroid scanner
000039769 7001_ $$0P:(DE-Juel1)133882$$aEngels, R.$$b1$$uFZJ
000039769 7001_ $$0P:(DE-Juel1)VDB2189$$aFuss, L.$$b2$$uFZJ
000039769 7001_ $$0P:(DE-Juel1)VDB5679$$aKemmerling, F. G.$$b3$$uFZJ
000039769 7001_ $$0P:(DE-Juel1)VDB2190$$aReinartz, R.$$b4$$uFZJ
000039769 7001_ $$0P:(DE-Juel1)131777$$aLangen, K. J.$$b5$$uFZJ
000039769 7001_ $$0P:(DE-Juel1)VDB2184$$aSchelten, J.$$b6$$uFZJ
000039769 7001_ $$0P:(DE-Juel1)VDB1841$$aZiemons, K.$$b7$$uFZJ
000039769 773__ $$0PERI:(DE-600)2025398-9$$a10.1109/23.940136$$gVol. 48, p. 625 - 627$$p625 - 627$$q48<625 - 627$$tIEEE transactions on nuclear science$$v48$$x0018-9499$$y2001
000039769 8564_ $$uhttps://juser.fz-juelich.de/record/39769/files/5273.pdf$$yOpenAccess
000039769 8564_ $$uhttps://juser.fz-juelich.de/record/39769/files/5273.jpg?subformat=icon-1440$$xicon-1440$$yOpenAccess
000039769 8564_ $$uhttps://juser.fz-juelich.de/record/39769/files/5273.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000039769 8564_ $$uhttps://juser.fz-juelich.de/record/39769/files/5273.jpg?subformat=icon-640$$xicon-640$$yOpenAccess
000039769 909CO $$ooai:juser.fz-juelich.de:39769$$pdnbdelivery$$pVDB$$pdriver$$popen_access$$popenaire
000039769 9131_ $$0G:(DE-Juel1)FUEK66$$bInformationstechnik$$k29.86.0$$lGrundlagenforschung zur Informationstechnik$$vIonen- und Lithographietechnik$$x0
000039769 9131_ $$0G:(DE-Juel1)FUEK101$$bInformationstechnik$$k52.20.0$$lDatenverarbeitung, Mathematik und Elektronik$$vOn-Line-Datenverarbeitung$$x1
000039769 9131_ $$0G:(DE-Juel1)FUEK89$$bLebenswissenschaften$$k40.10.0$$lMedizinforschung und -technik$$vSignaltransduktion$$x2
000039769 9141_ $$y2001
000039769 915__ $$0StatID:(DE-HGF)0010$$aJCR/ISI refereed
000039769 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000039769 9201_ $$0I:(DE-Juel1)VDB42$$d31.12.2006$$gISG$$kISG-2$$lInstitut für Bio- und Chemosensoren$$x0
000039769 9201_ $$0I:(DE-Juel1)ZEL-20090406$$gZEL$$kZEL$$lZentralinstitut für Elektronik$$x1
000039769 9201_ $$0I:(DE-Juel1)VDB54$$d31.12.2006$$gIME$$kIME$$lInstitut für Medizin$$x2
000039769 970__ $$aVDB:(DE-Juel1)5273
000039769 9801_ $$aFullTexts
000039769 980__ $$aVDB
000039769 980__ $$aJUWEL
000039769 980__ $$aConvertedRecord
000039769 980__ $$ajournal
000039769 980__ $$aI:(DE-Juel1)IBN-2-20090406
000039769 980__ $$aI:(DE-Juel1)ZEA-2-20090406
000039769 980__ $$aI:(DE-Juel1)INB-3-20090406
000039769 980__ $$aUNRESTRICTED
000039769 980__ $$aFullTexts
000039769 981__ $$aI:(DE-Juel1)PGI-4-20110106
000039769 981__ $$aI:(DE-Juel1)IBN-2-20090406
000039769 981__ $$aI:(DE-Juel1)ZEA-2-20090406
000039769 981__ $$aI:(DE-Juel1)INB-3-20090406
000039769 981__ $$aI:(DE-Juel1)ZEL-20090406