% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@ARTICLE{Barthel:837913,
      author       = {Barthel, Juri and Lentzen, Markus and Thust, Andreas},
      title        = {{R}esponse to the comment by {C}. {K}isielowsky, {H}.{A}.
                      {C}alderon, {F}.{R}. {C}hen, {S}. {H}elveg, {J}.{R}.
                      {J}inschek, {P}. {S}pecht, {D}. van {D}yck on the article
                      "{O}n the influence of the electron dose-rate on the {HRTEM}
                      {I}mage contrast" by {J}. {B}arthel, {M}. {L}entzen, {A}.
                      {T}hust},
      journal      = {Ultramicroscopy},
      volume       = {179},
      issn         = {0304-3991},
      address      = {Amsterdam},
      publisher    = {Elsevier Science},
      reportid     = {FZJ-2017-06683},
      pages        = {113 - 115},
      year         = {2017},
      abstract     = {In a recent article [1] we examined the influence of the
                      applied electron dose rate on the magnitude of the image
                      contrast in high-resolution transmission electron microscopy
                      (HRTEM). We concluded that the magnitude of the image
                      contrast is not substantially affected by the applied
                      electron dose rate. This result is in obvious contradiction
                      to numerous earlier publications by Kisielowski and
                      coworkers [2–7], who commented our recent article due to
                      this contradiction. The present short communication is a
                      response to the comment of Kisielowski and coworkers on our
                      recent article, where we provide additional arguments
                      supporting our initial findings and conclusions on the
                      magnitude of the image contrast in HRTEM.},
      cin          = {ER-C-1 / ER-C-2},
      ddc          = {570},
      cid          = {I:(DE-Juel1)ER-C-1-20170209 / I:(DE-Juel1)ER-C-2-20170209},
      pnm          = {143 - Controlling Configuration-Based Phenomena (POF3-143)},
      pid          = {G:(DE-HGF)POF3-143},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:000403985600016},
      doi          = {10.1016/j.ultramic.2017.04.004},
      url          = {https://juser.fz-juelich.de/record/837913},
}