Abstract: The Cooler Synchrotron COSY can store and deliver protonand deuteron beam in the momentum range from 0.3GeV/c to 3.65 GeV/c for internal and external experiments.New requirements of the Jülich Electric Dipole MomentInvestigation (JEDI) experiment requires a RMS beam orbitdistortion smaller than 100 µm. This requirement lead so farto the replacement of the BPM readout electronics, an introductionof a slow beam orbit correction and feedback systemand the re-alignment of the magnets. All three projects areclose to completion, therefore first results are presented.