000863099 001__ 863099
000863099 005__ 20240619091249.0
000863099 0247_ $$2doi$$a10.3390/s19112599
000863099 0247_ $$2Handle$$a2128/22717
000863099 0247_ $$2altmetric$$aaltmetric:63276325
000863099 0247_ $$2pmid$$apmid:31181672
000863099 0247_ $$2WOS$$aWOS:000472133300177
000863099 037__ $$aFZJ-2019-03213
000863099 082__ $$a620
000863099 1001_ $$0P:(DE-Juel1)168292$$aAchtsnicht, Stefan$$b0
000863099 245__ $$aMultiplex Detection of Different Magnetic Beads Using Frequency Scanning in Magnetic Frequency Mixing Technique
000863099 260__ $$aBasel$$bMDPI$$c2019
000863099 3367_ $$2DRIVER$$aarticle
000863099 3367_ $$2DataCite$$aOutput Types/Journal article
000863099 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1568036475_22202
000863099 3367_ $$2BibTeX$$aARTICLE
000863099 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000863099 3367_ $$00$$2EndNote$$aJournal Article
000863099 520__ $$aIn modern bioanalytical methods, it is often desired to detect several targets in one sample within one measurement. Immunological methods including those that use superparamagnetic beads are an important group of techniques for these applications. The goal of this work is to investigate the feasibility of simultaneously detecting different superparamagnetic beads acting as markers using the magnetic frequency mixing technique. The frequency of the magnetic excitation field is scanned while the lower driving frequency is kept constant. Due to the particles’ nonlinear magnetization, mixing frequencies are generated. To record their amplitude and phase information, a direct digitization of the pickup-coil’s signal with subsequent Fast Fourier Transformation is performed. By synchronizing both magnetic fields, a stable phase information is gained. In this research, it is shown that the amplitude of the dominant mixing component is proportional to the amount of superparamagnetic beads inside a sample. Additionally, it is shown that the phase does not show this behaviour. Excitation frequency scans of different bead types were performed, showing different phases, without correlation to their diverse amplitudes. Two commercially available beads were selected and a determination of their amount in a mixture is performed as a demonstration for multiplex measurements.
000863099 536__ $$0G:(DE-HGF)POF3-523$$a523 - Controlling Configuration-Based Phenomena (POF3-523)$$cPOF3-523$$fPOF III$$x0
000863099 588__ $$aDataset connected to CrossRef
000863099 7001_ $$0P:(DE-Juel1)173858$$aPourshahidi, Ali Mohammad$$b1
000863099 7001_ $$0P:(DE-Juel1)128713$$aOffenhäusser, Andreas$$b2
000863099 7001_ $$0P:(DE-Juel1)128697$$aKrause, Hans-Joachim$$b3$$eCorresponding author
000863099 773__ $$0PERI:(DE-600)2052857-7$$a10.3390/s19112599$$gVol. 19, no. 11, p. 2599 -$$n11$$p2599 -$$tSensors$$v19$$x1424-8220$$y2019
000863099 8564_ $$uhttps://juser.fz-juelich.de/record/863099/files/Invoice_MDPI_sensors-516331_962.09EUR.pdf
000863099 8564_ $$uhttps://juser.fz-juelich.de/record/863099/files/Invoice_MDPI_sensors-516331_962.09EUR.pdf?subformat=pdfa$$xpdfa
000863099 8564_ $$uhttps://juser.fz-juelich.de/record/863099/files/sensors-19-02599.pdf$$yOpenAccess
000863099 8564_ $$uhttps://juser.fz-juelich.de/record/863099/files/sensors-19-02599.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000863099 8767_ $$8sensors-516331$$92019-06-05$$d2019-06-06$$eAPC$$jZahlung erfolgt
000863099 909CO $$ooai:juser.fz-juelich.de:863099$$pdnbdelivery$$popenCost$$pVDB$$pdriver$$pOpenAPC$$popen_access$$popenaire
000863099 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)168292$$aForschungszentrum Jülich$$b0$$kFZJ
000863099 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)173858$$aForschungszentrum Jülich$$b1$$kFZJ
000863099 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)128713$$aForschungszentrum Jülich$$b2$$kFZJ
000863099 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)128697$$aForschungszentrum Jülich$$b3$$kFZJ
000863099 9131_ $$0G:(DE-HGF)POF3-523$$1G:(DE-HGF)POF3-520$$2G:(DE-HGF)POF3-500$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bKey Technologies$$lFuture Information Technology - Fundamentals, Novel Concepts and Energy Efficiency (FIT)$$vControlling Configuration-Based Phenomena$$x0
000863099 9141_ $$y2019
000863099 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000863099 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000863099 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000863099 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bSENSORS-BASEL : 2017
000863099 915__ $$0StatID:(DE-HGF)0501$$2StatID$$aDBCoverage$$bDOAJ Seal
000863099 915__ $$0StatID:(DE-HGF)0500$$2StatID$$aDBCoverage$$bDOAJ
000863099 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000863099 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000863099 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000863099 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000863099 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000863099 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000863099 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000863099 915__ $$0StatID:(DE-HGF)0320$$2StatID$$aDBCoverage$$bPubMed Central
000863099 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List
000863099 920__ $$lyes
000863099 9201_ $$0I:(DE-Juel1)ICS-8-20110106$$kICS-8$$lBioelektronik$$x0
000863099 9801_ $$aAPC
000863099 9801_ $$aFullTexts
000863099 980__ $$ajournal
000863099 980__ $$aVDB
000863099 980__ $$aUNRESTRICTED
000863099 980__ $$aI:(DE-Juel1)ICS-8-20110106
000863099 980__ $$aAPC
000863099 981__ $$aI:(DE-Juel1)IBI-3-20200312