245 _ _ |a Variation of Impedance in Lead-Acid Batteries in the Presence of Acid Stratification
260 _ _ |a Basel
|c 2018
|b MDPI
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1581002852_22019
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Acid stratification is a common issue in lead-acid batteries. The density of the electrolyte rises from the top to the bottom and causes inhomogeneous current distribution over the electrodes. The consequences are unequal aging processes provoking earlier battery failure. In stationary applications electrolyte circulation pumps are sporadical installed in the battery to mix the acid. For automotive applications passive mixing systems are implemented by some battery manufacturers against stratification. Stratification does not show any distinct voltage-current profile to be recognizable online. However, it increases the voltage and affects the impedance, which both are essential information for diagnostic purpose. Impedance spectra were performed here on lead-acid test cells with adjusted stratification levels to analyze the influence on the impedance in details. It is observed, that the high-frequency impedance is decreased in the stratified cell and that in contrast to this the charge-transfer resistance is increased. Based on simulations with a spatially-resolved equivalent electrical circuit the increased charge-transfer resistance could be explained with an inhomogeneous State-of-Charge resulting in an accumulation of sulfate crystals in the bottom part of the electrodes. These sulfate crystals further affected recorded impedance spectra after the electrolyte was homogenized.
536 _ _ |a 131 - Electrochemical Storage (POF3-131)
|0 G:(DE-HGF)POF3-131
|c POF3-131
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a Huck, Moritz
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Badeda, Julia
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Zorer, Caner
|0 P:(DE-HGF)0
|b 3
700 1 _ |a Komut, Kuebra
|0 P:(DE-HGF)0
|b 4
700 1 _ |a Yu, Qianru
|0 P:(DE-HGF)0
|b 5
700 1 _ |a Sauer, Dirk
|0 P:(DE-Juel1)172625
|b 6
773 _ _ |a 10.3390/app8071018
|g Vol. 8, no. 7, p. 1018 -
|0 PERI:(DE-600)2704225-X
|n 7
|p 1018 -
|t Applied Sciences
|v 8
|y 2018
|x 2076-3417
856 4 _ |y OpenAccess
|u https://juser.fz-juelich.de/record/866896/files/applsci-08-01018-published.pdf
856 4 _ |y OpenAccess
|x pdfa
|u https://juser.fz-juelich.de/record/866896/files/applsci-08-01018-published.pdf?subformat=pdfa
909 C O |o oai:juser.fz-juelich.de:866896
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 0
|6 P:(DE-HGF)0
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 1
|6 P:(DE-HGF)0
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 3
|6 P:(DE-HGF)0
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 4
|6 P:(DE-HGF)0
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 5
|6 P:(DE-HGF)0
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 6
|6 P:(DE-Juel1)172625
913 1 _ |a DE-HGF
|l Speicher und vernetzte Infrastrukturen
|1 G:(DE-HGF)POF3-130
|0 G:(DE-HGF)POF3-131
|2 G:(DE-HGF)POF3-100
|v Electrochemical Storage
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
|b Energie
914 1 _ |y 2019
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1160
|2 StatID
|b Current Contents - Engineering, Computing and Technology
915 _ _ |a Creative Commons Attribution CC BY 4.0
|0 LIC:(DE-HGF)CCBY4
|2 HGFVOC
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b APPL SCI-BASEL : 2017
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0501
|2 StatID
|b DOAJ Seal
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0500
|2 StatID
|b DOAJ
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a Peer Review
|0 StatID:(DE-HGF)0030
|2 StatID
|b DOAJ : Blind peer review
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1150
|2 StatID
|b Current Contents - Physical, Chemical and Earth Sciences
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)IEK-12-20141217
|k IEK-12
|l Helmholtz-Institut Münster Ionenleiter für Energiespeicher
|x 0
980 1 _ |a FullTexts
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)IEK-12-20141217
981 _ _ |a I:(DE-Juel1)IMD-4-20141217


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21