000878575 001__ 878575
000878575 005__ 20240708133542.0
000878575 0247_ $$2doi$$a10.1016/j.fusengdes.2019.03.176
000878575 0247_ $$2ISSN$$a0920-3796
000878575 0247_ $$2ISSN$$a1873-7196
000878575 0247_ $$2Handle$$a2128/25567
000878575 0247_ $$2WOS$$aWOS:000488313700196
000878575 037__ $$aFZJ-2020-02918
000878575 082__ $$a530
000878575 1001_ $$0P:(DE-Juel1)169616$$aGonzalez, W.$$b0$$eCorresponding author
000878575 245__ $$aConceptual studies on spectroscopy and radiation diagnostic systems for plasma control on DEMO
000878575 260__ $$aNew York, NY [u.a.]$$bElsevier$$c2019
000878575 3367_ $$2DRIVER$$aarticle
000878575 3367_ $$2DataCite$$aOutput Types/Journal article
000878575 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1599544103_31238
000878575 3367_ $$2BibTeX$$aARTICLE
000878575 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000878575 3367_ $$00$$2EndNote$$aJournal Article
000878575 520__ $$aThe roadmap to the realization of fusion energy describes a path towards the development of a DEMO tokamak reactor, which is expected to provide electricity into the grid by the mid of the century (Romanelli, 2013). The DEMO diagnostic and control (D&C) system must provide measurements with high reliability and accuracy, not only constrained by space restrictions in the blanket, but also by adverse effects induced by neutron, gamma radiation and particle fluxes. In view of the concept development for DEMO control, an initial selection of suitable diagnostics has been obtained (Biel et al., 2019). This initial group of diagnostic consists of 6 methods: Microwave diagnostics, thermo-current measurements, magnetic diagnostics, neutron/gamma diagnostics, IR interferometry/polarimetry, and a variety of spectroscopic and radiation measurement systems. A key aspect for the implementation, performance and lifetime assessment of these systems on DEMO, is mainly attributable to their location, that must be well protected, and meet their own set of specific requirements. With this in mind, sightline analysis, space consumption and the evaluation of optical systems are the main assessment tools to obtain a high level of integration, reliability and robustness of all this instrumentation; essential features in future commercial fusion power nuclear plants. In this paper we concentrate on spectroscopic and radiation measurement systems that require sightlines over a large range of plasma regions and inner reactor surfaces. Moreover, this paper outlines the main results and strategies adopted in this early stage of DEMO conceptual design to assess the feasibility of this initial set of diagnostic methods based on sightlines and the integration of these needed for DEMO D&C.
000878575 536__ $$0G:(DE-HGF)POF3-174$$a174 - Plasma-Wall-Interaction (POF3-174)$$cPOF3-174$$fPOF III$$x0
000878575 588__ $$aDataset connected to CrossRef
000878575 7001_ $$0P:(DE-Juel1)129967$$aBiel, W.$$b1
000878575 7001_ $$0P:(DE-Juel1)4596$$aMertens, Ph.$$b2
000878575 7001_ $$0P:(DE-Juel1)5089$$aTokar, M.$$b3
000878575 7001_ $$0P:(DE-Juel1)5739$$aMarchuk, O.$$b4$$ufzj
000878575 7001_ $$0P:(DE-Juel1)157640$$aLinsmeier, Ch.$$b5
000878575 773__ $$0PERI:(DE-600)1492280-0$$a10.1016/j.fusengdes.2019.03.176$$gVol. 146, p. 2297 - 2301$$p2297 - 2301$$tFusion engineering and design$$v146$$x0920-3796$$y2019
000878575 8564_ $$uhttps://juser.fz-juelich.de/record/878575/files/Postprint_Gonzalez_Conceptual%20studies.pdf$$yPublished on 2019-04-05. Available in OpenAccess from 2021-04-05.
000878575 8564_ $$uhttps://juser.fz-juelich.de/record/878575/files/Postprint_Gonzalez_Conceptual%20studies.pdf?subformat=pdfa$$xpdfa$$yPublished on 2019-04-05. Available in OpenAccess from 2021-04-05.
000878575 909CO $$ooai:juser.fz-juelich.de:878575$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000878575 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129967$$aForschungszentrum Jülich$$b1$$kFZJ
000878575 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)4596$$aForschungszentrum Jülich$$b2$$kFZJ
000878575 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)5739$$aForschungszentrum Jülich$$b4$$kFZJ
000878575 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)157640$$aForschungszentrum Jülich$$b5$$kFZJ
000878575 9131_ $$0G:(DE-HGF)POF3-174$$1G:(DE-HGF)POF3-170$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lKernfusion$$vPlasma-Wall-Interaction$$x0
000878575 9141_ $$y2020
000878575 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2020-01-09
000878575 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2020-01-09
000878575 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2020-01-09
000878575 915__ $$0StatID:(DE-HGF)0530$$2StatID$$aEmbargoed OpenAccess
000878575 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bFUSION ENG DES : 2018$$d2020-01-09
000878575 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2020-01-09
000878575 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index$$d2020-01-09
000878575 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2020-01-09
000878575 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2020-01-09
000878575 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2020-01-09
000878575 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2020-01-09
000878575 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2020-01-09$$wger
000878575 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2020-01-09
000878575 920__ $$lyes
000878575 9201_ $$0I:(DE-Juel1)IEK-4-20101013$$kIEK-4$$lPlasmaphysik$$x0
000878575 9801_ $$aFullTexts
000878575 980__ $$ajournal
000878575 980__ $$aVDB
000878575 980__ $$aUNRESTRICTED
000878575 980__ $$aI:(DE-Juel1)IEK-4-20101013
000878575 981__ $$aI:(DE-Juel1)IFN-1-20101013