000894832 001__ 894832
000894832 005__ 20240712084622.0
000894832 0247_ $$2doi$$a10.3390/fluids6030100
000894832 0247_ $$2Handle$$a2128/28609
000894832 0247_ $$2altmetric$$aaltmetric:102638798
000894832 0247_ $$2WOS$$aWOS:000633647400001
000894832 037__ $$aFZJ-2021-03416
000894832 082__ $$a530
000894832 1001_ $$0P:(DE-Juel1)130361$$aKelm, Stephan$$b0$$eCorresponding author
000894832 245__ $$aThe Tailored CFD Package ‘containmentFOAM’ for Analysis of Containment Atmosphere Mixing, H2/CO Mitigation and Aerosol Transport
000894832 260__ $$aBelgrade$$bMDPI$$c2021
000894832 3367_ $$2DRIVER$$aarticle
000894832 3367_ $$2DataCite$$aOutput Types/Journal article
000894832 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1633324831_3556
000894832 3367_ $$2BibTeX$$aARTICLE
000894832 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000894832 3367_ $$00$$2EndNote$$aJournal Article
000894832 520__ $$aThe severe reactor accident at Fukushima Daiichi Nuclear Power Plant (2011) has confirmed the need to understand the flow and transport processes of steam and combustible gases inside the containment and connected buildings. Over several years, Computational Fluid Dynamics (CFD) models, mostly based on proprietary solvers, have been developed to provide highly resolved insights; supporting the assessment of effectiveness of safety measures and possible combustion loads challenging the containment integrity. This paper summarizes the design and implementation of containmentFOAM, a tailored solver and model library based on OpenFOAM®. It is developed in support of Research & Development related to containment flows, mixing processes, pressurization, and assessment of passive safety systems. Based on preliminary separate-effect verification and validation results, an application oriented integral validation case is presented on the basis of an experiment on gas mixing and H2 mitigation by means of passive auto-catalytic recombiners in the THAI facility (Becker Technologies, Eschborn, Germany). The simulation results compare well with the experimental data and demonstrate the general applicability of containmentFOAM for technical scale analysis. Concluding the paper, the strategy for dissemination of the code and measures implemented to minimize potential user errors are outlined
000894832 536__ $$0G:(DE-HGF)POF4-1421$$a1421 - Design Basis Accidents and Materials Research (POF4-142)$$cPOF4-142$$fPOF IV$$x0
000894832 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
000894832 7001_ $$0P:(DE-Juel1)169791$$aKampili, Manohar$$b1
000894832 7001_ $$0P:(DE-Juel1)173874$$aLiu, Xiongguo$$b2
000894832 7001_ $$0P:(DE-Juel1)186699$$aGeorge, Allen$$b3
000894832 7001_ $$0P:(DE-Juel1)176622$$aSchumacher, Daniel$$b4
000894832 7001_ $$0P:(DE-Juel1)5471$$aDruska, Claudia$$b5
000894832 7001_ $$0P:(DE-Juel1)23016$$aStruth, Stephan$$b6
000894832 7001_ $$0P:(DE-Juel1)23142$$aKuhr, Astrid$$b7
000894832 7001_ $$0P:(DE-Juel1)179473$$aRamacher, Lucian$$b8
000894832 7001_ $$0P:(DE-Juel1)130314$$aAllelein, Hans-Josef$$b9
000894832 7001_ $$0P:(DE-HGF)0$$aPrakash, K. Arul$$b10
000894832 7001_ $$0P:(DE-HGF)0$$aKumar, G. Vijaya$$b11
000894832 7001_ $$0P:(DE-Juel1)178896$$aCammiade, Liam M. F.$$b12
000894832 7001_ $$0P:(DE-Juel1)179512$$aJi, Ruiyun$$b13
000894832 773__ $$0PERI:(DE-600)2882362-X$$a10.3390/fluids6030100$$gVol. 6, no. 3, p. 100 -$$n3$$p100 -$$tFluids$$v6$$x2311-5521$$y2021
000894832 8564_ $$uhttps://juser.fz-juelich.de/record/894832/files/Invoice_MDPI_fluids-1110911_1190.00CHF.pdf
000894832 8564_ $$uhttps://juser.fz-juelich.de/record/894832/files/fluids-06-00100-v2.pdf$$yOpenAccess
000894832 8767_ $$81110911$$92021-02-25$$d2021-03-02$$eAPC$$jZahlung erfolgt$$z1190 CHF, Belegnr. 1200164294 / 2021
000894832 909CO $$ooai:juser.fz-juelich.de:894832$$pdnbdelivery$$popenCost$$pVDB$$pdriver$$pOpenAPC$$popen_access$$popenaire
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130361$$aForschungszentrum Jülich$$b0$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)169791$$aForschungszentrum Jülich$$b1$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)173874$$aForschungszentrum Jülich$$b2$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)186699$$aForschungszentrum Jülich$$b3$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)176622$$aForschungszentrum Jülich$$b4$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)5471$$aForschungszentrum Jülich$$b5$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)23016$$aForschungszentrum Jülich$$b6$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)23142$$aForschungszentrum Jülich$$b7$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)179473$$aForschungszentrum Jülich$$b8$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130314$$aForschungszentrum Jülich$$b9$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)178896$$aForschungszentrum Jülich$$b12$$kFZJ
000894832 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)179512$$aForschungszentrum Jülich$$b13$$kFZJ
000894832 9131_ $$0G:(DE-HGF)POF4-142$$1G:(DE-HGF)POF4-140$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1421$$aDE-HGF$$bForschungsbereich Energie$$lNukleare Entsorgung, Sicherheit und Strahlenforschung (NUSAFE II)$$vSicherheit von Kernreaktoren$$x0
000894832 9141_ $$y2021
000894832 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2020-09-02
000894832 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000894832 915__ $$0StatID:(DE-HGF)0501$$2StatID$$aDBCoverage$$bDOAJ Seal$$d2020-09-02
000894832 915__ $$0StatID:(DE-HGF)0112$$2StatID$$aWoS$$bEmerging Sources Citation Index$$d2020-09-02
000894832 915__ $$0StatID:(DE-HGF)0500$$2StatID$$aDBCoverage$$bDOAJ$$d2020-09-02
000894832 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2020-09-02
000894832 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000894832 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bDOAJ : Blind peer review$$d2020-09-02
000894832 915__ $$0StatID:(DE-HGF)0561$$2StatID$$aArticle Processing Charges$$d2020-09-02
000894832 915__ $$0StatID:(DE-HGF)0700$$2StatID$$aFees$$d2020-09-02
000894832 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2020-09-02
000894832 920__ $$lyes
000894832 9201_ $$0I:(DE-Juel1)IEK-6-20101013$$kIEK-6$$lNukleare Entsorgung und Reaktorsicherheit$$x0
000894832 9801_ $$aAPC
000894832 9801_ $$aFullTexts
000894832 980__ $$ajournal
000894832 980__ $$aVDB
000894832 980__ $$aI:(DE-Juel1)IEK-6-20101013
000894832 980__ $$aAPC
000894832 980__ $$aUNRESTRICTED
000894832 981__ $$aI:(DE-Juel1)IFN-2-20101013